    Novel 3-dimensional motion analysis method for measuring the lumbar spine range of motion: repeatability and reliability compared with an electrogoniometer.

    • Michio Tojima, Naoshi Ogata, Arito Yozu, Masahiko Sumitani, and Nobuhiko Haga.
    • *Department of Rehabilitation Medicine, The University of Tokyo, Tokyo, Japan †Department of Rehabilitation Medicine, The University of Tokyo Hospital, Japan ‡Department of Sensory-Recognition and Locomotive-Function Sciences in the Super-Aged Society, The University of Tokyo, Tokyo, Japan; and §Department of Medical Engineering, The University of Tokyo Hospital, Tokyo, Japan.
    • Spine. 2013 Oct 1; 38 (21): E1327-33.

    Study DesignRepeatability and reliability for measuring methods for real-time lumbar range of motion.ObjectiveWe established a novel set of marker positions for 3-dimensional motion analysis (VICON system) to determine lumbar spine range of motion (LROM) and lumbar motion precisely; we compared the repeatability and reliability of VICON system with those of an electrogoniometer.Summary Of Background DataThe assessment of the LROM using x-ray is still one of the most precise methods, despite the radiation exposure. To avoid this, alternative methods, such as the VICON system and electrogoniometer, have been widely used. No study has reported the repeatability and reliability of LROM measurements using a VICON system and electrogoniometer.MethodsThe VICON system and electrogoniometer measured LROM and lumbar motion in 7 healthy males during 7 days. Differences between both systems were analyzed using Bland-Altman plots. Repeatability and reliability of the LROM measurements was assessed using coefficients of multiple correlations and intraclass correlation coefficients, respectively. Standard error of measurement was calculated to quantify the systematic error in LROM measurements.ResultsThe mean maximum LROM values using the VICON system/electrogoniometer were 42°/52° for flexion, 17°/24° for extension, 16°/16° for lateral bending, and 8°/2° for axial rotation, respectively. Between VICON system and the electrogoniometer, Bland-Altman plots revealed no discrepancies in LROM values except for flexion.Coefficients of multiple correlations for LROM showed excellent repeatability. LROM measurements with VICON system showed excellent reliability for flexion and extension and fair-to-good reliability for other motions. LROM measurements with the electrogoniometer showed excellent reliability for flexion and fair-to-good reliability for other motions. Except for axial rotation, maximum intraclass correlation coefficients using VICON system were more reliable than the electrogoniometer for measuring lumbar motion.ConclusionVICON system with our novel marker set allows practical and reliable longitudinal assessment of dynamic LROM.Level Of EvidenceN/A.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…