• The heart surgery forum · Mar 2020

    Early Results of a Novel Single-Stage Hybrid Aortic Arch Replacement Technique to Reduce Bypass and Circulatory Arrest Duration.

    • Castigliano Murthy Bhamidipati and Jay D Pal.
    • Division of Cardiothoracic Surgery, Department of Surgery, Oregon Health and Science University, Portland, Oregon, USA.
    • Heart Surg Forum. 2020 Mar 9; 23 (2): E107-E113.

    ObjectiveHybrid repair procedures of the aortic arch have been utilized to reduce surgical risks and apply this therapy to patients who would not traditionally be candidates for open surgical repair.  We present a variation on the frozen elephant trunk technique to further reduce cardiopulmonary bypass and circulatory arrest duration.MethodsAfter initiation of cardiopulmonary bypass and during systemic cooling, a wire is advanced from the femoral artery into the aortic arch.  In the case of aortic dissection, intravascular ultrasound is used to confirm true lumen placement.  Under circulatory arrest, the proximal aortic arch is resected and the wire externalized.  Antegrade deployment of a stent graft is performed into the aortic arch and proximal descending aorta.  The ascending aortic graft is sewn to the cut end of the aorta, incorporating the stent graft.  The graft is cannulated and cardiopulmonary bypass reinitiated.  The remainder of the arch replacement is performed during re-warming.ResultsTwenty two patients underwent this novel hybrid arch replacement procedure for aortic pseudoaneurysm, aortic dissection, or aneurysm.  In comparison to the frozen elephant trunk procedure, where a dacron graft is inserted into the descending aorta, and later fixed with an endograft, this technique allows for immediate distal fixation.  In the case of aortic dissection, there is immediate expansion of the true lumen with distal seal, potentially obviating the need for additional procedures.  Mean duration of follow up is 12 months (range 1 - 14 months).  The mean duration of cardiopulmonary bypass was 109.32 ±3.14 minutes.  The mean duration of circulatory arrest was 18.00 ±1.33 minutes at a mean temperature of 23.64 ±0.58 degrees Celsius.  There were no mortalities, no permanent disabling strokes, and no renal failure (requiring dialysis).ConclusionsThis novel hybrid technique for aortic arch replacement is safe, significantly reduces cardiopulmonary bypass and circulatory arrest times, and is performed readily without need for fluoroscopy.  In patients with thoracoabdominal aneurysms, the stent graft can be used as an elephant trunk for further thoracoabdominal aneurysm repair or branched thoracic endovascular aortic repair procedures.2020 Forum Multimedia Publishing, LLC

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…