Arch Orthop Trauma Surg · May 2014
Comparative StudyFate of large donor site defects in osteochondral transfer procedures in the knee joint with and without TruFit plugs.
- Verena M A Quarch, Elena Enderle, Joachim Lotz, and Karl-Heinz Frosch.
- Department of Trauma and Reconstructive Surgery, Asklepios Clinic St. Georg, Lohmühlenstr. 5, 20099, Hamburg, Germany.
- Arch Orthop Trauma Surg. 2014 May 1; 134 (5): 657-66.
IntroductionBecause of the potential donor site morbidity, cartilage lesions of more than 3 cm(2) in size are considered to be critical regarding autologous osteochondral transplantation (OCT). In this study, the potential donor site morbidity for large defects should be reduced by means of OBI TruFit Plugs.Materials And MethodsAn autologous OCT was carried out on 37 patients and the cylinders were received from the dorsal medial femoral condyle. The donor site defects of 21 patients (average defect size 5.5 cm(2)) were filled with artificial TruFit cylinders (study group); the donor site defects (average defect size 4.6 cm(2)) were left untreated for 16 patients.ResultsIn the study group, the Tegner, Western Ontario and McMaster Universities (WOMAC), knee society score, and visual analogue scale pain scores improved from preoperatively 3.2 (±0.8), 60.9 (±41.6), 133.6 (±27.1), and 4.8 (±2.3) points, respectively, to 3.9 (±0.6), 35.5 (±27.1), 177.8 (±16.6), and 3.3 (±2.9) points, respectively, at the time of the second follow-up; the control group's preoperative score values came to 2.8 (±0.9), 73.3 (±50.2), 123.8 (±41.5), and 5.3 (±2.7) points, respectively, and changed to 3.6 (±0.8), 41.4 (±28.8), 179.3 (±17.5), and 3.1 (±2.0) points, respectively, at the time of the second follow-up. The smaller the initial chondral defect was in the study group, the better the WOMAC score values became (p < 0.05). The modified Henderson score at the study group's donor sites improved from 19.2 (±3.3) to 13.7 (±2.1) points (p < 0.001); the control group's score values for the donor sites were 18.3 (±3.4) and 15.4 (±4.4) points (p = 0.0015).ConclusionsOCT is an effective therapy even for large chondral defects >3 cm(2). By filling the defects with TruFit implants, no clinical improvements could be found since the donor site morbidity was already low anyway. However, the regeneration of defects filled with TruFit implants took more than 2 years.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.