    Biomechanics of spinal hemiepiphysiodesis for fusionless scoliosis treatment using titanium implant.

    • Matthew T Coombs, David L Glos, Eric J Wall, Jay Kim, and Donita I Bylski-Austrow.
    • *University of Cincinnati, Cincinnati, OH; and †Department of Orthopaedics, Cincinnati Children's Hospital Medical Center, Cincinnati, OH.
    • Spine. 2013 Nov 1;38(23):E1454-60.

    Study DesignIn vitro study of the effect of hemiepiphyseal implant on biomechanical properties of porcine thoracic motion segments.ObjectiveDetermine whether implantation of a titanium clip-screw construct alters spine biomechanical properties.Summary Of Background DataGrowth modification is under investigation as a treatment of early adolescent idiopathic scoliosis. Biomechanical property changes due to device implantation are essential to characterize immediate postoperative treatment effects.MethodsIn vitro biomechanical tests were conducted on 18 thoracic functional spinal units. Specimens were tested before and after implantation of a clip-screw construct in lateral bending, flexion-extension, or axial rotation (n = 6 per loading direction). Pure moments were applied, and range of motion, stiffness, and neutral zone were measured. Axial translations were determined bilaterally.ResultsImplantation of the clip-screw construct decreased range of motion in lateral bending by 19% (P < 0.0003), flexion-extension by 11% (P < 0.04), and axial rotation by 8%. Mean stiffness in lateral bending toward and away from the treated side increased by 20% (P < 0.007) and 33%, respectively. In flexion and extension, mean stiffness increased by 10% and 16%, respectively. Treatment decreased the neutral zone in lateral bending toward and away from the instrumented side by 30% (P < 0.0003) and 47% (P < 0.02), respectively. In flexion and extension, neutral zone decreased by 20% (P < 0.04) and 26% (P < 0.007), respectively. In axial rotation toward and away from the treated side, mean neutral zone decreased by 22% (P < 0.04) and 7%, respectively. Range of axial translation decreased on the ipsilateral side by 49% (P < 0.001) and increased on the contralateral side by 17%.ConclusionImplantation of a titanium clip-screw construct decreased range of motion by less than one-fifth, increased stiffness by one-third or less, and decreased the neutral zone by less than one-half. Range of axial translation decreased on the instrumented side and increased contralaterally. This study suggests that most of the flexibility of the spine is preserved in the immediate postoperative period after implantation of the spinal hemiepiphyseal construct.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.