- Joseph K Lee, Jaime Gomez, Christopher Michelsen, Yongjung Kim, Mark Moldavsky, Suresh Reddy Chinthakunta, and Saif Khalil.
- *New York Presbyterian Hospital/Columbia University Medical Center, New York, NY; and †Globus Medical Inc., Audubon, PA.
- Spine. 2013 Oct 15;38(22):1913-9.
Study DesignAn in vitro biomechanical study.ObjectiveTo perform in vitro biomechanical testing on a lumbar spine using a 6-degree-of-freedom machine. To compare the range of motion (ROM), intradiscal pressure, and facet force of different 3-level dynamic stabilization constructs with traditional rigid constructs. To determine the effect of decreasing the stiffness of the dynamic construct on the various parameters.Summary Of Background DataDynamic stabilization systems are a surgical option that may minimize the development of adjacent segment disease.MethodsSeven T12-S1 specimens were tested at ± 7.5 Nm in flexion-extension, lateral bending, and axial rotation. The testing sequence was (1) intact, (2) intact with facet sensors, (3) L3-S1 rigid (3R), (4) L3-L4 dynamic and L4-S1 rigid (1D-2R A), (5) L3-L5 dynamic and L5-S1 rigid (2D-1R A), and (6) L3-S1 dynamic (3D A). Constructs 1D-2R A, 2D-1R A, and 3D A were tested again with the specialized designs of B and C of decreased stiffness. ROM, intradiscal pressure, and facet force were measured.ResultsIn all loading modes there was a trend of increasing motion with decreased stiffness. Significant differences were seen with more dynamic stabilization levels but no significance was seen with only decreasing the stiffness. 3R facet force at the caudal instrumented level significantly decreased compared with intact and dynamic stabilization constructs during axial rotation.ConclusionBiomechanical testing resulted in a trend of increased ROM across instrumented levels as the stiffness was decreased. Dynamic stabilization increased the ROM across instrumented levels compared with rigid rods. These results suggest that decreasing the stiffness of the construct may lessen the probability of adjacent-level disease. Although the specialized devices are not commercially available, clinical data would be necessary for a clearer understanding of adjacent level effects and to confirm the in vitro biomechanical findings.Level Of EvidenceN/A.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.