-
- Rami W Eldaya, Matthew S Parsons, Hilary L P Orlowski, Martin N Reis, and Aseem Sharma.
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 South Kingshighway Boulevard, St. Louis, MO, 63110, USA. rami.eldaya@wustl.edu.
- Eur Spine J. 2021 Aug 1; 30 (8): 2150-2156.
Background And PurposeVisualization of annular fissures on MRI is becoming increasingly important but remains challenging. Our purpose was to test whether an image processing algorithm could improve detection of annular fissures.Materials And MethodsIn this retrospective study, two neuroradiologists identified 56 IVDs with annular fissures and 97 IVDs with normal annulus fibrosus in lumbar spine MRIs of 101 patients (58 M, 43 F; age ± SD 15.1 ± 3.0 years). Signal intensities of diseased and normal annulus fibrosus, and contrast-to-noise ratio between them on sagittal T2-weighted images were calculated before and after processing with a proprietary software. Effect of processing on detection of annular fissures by two masked neuroradiologists was also studied for IVDs with Pfirrmann grades of ≤ 2 and > 2.ResultsMean (SD) signal baseline intensities of diseased and normal annulus fibrosus were 57.6 (23.3) and 24.4 (7.8), respectively (p < 0.001). Processing increased (p < 0.001) the mean (SD) intensity of diseased annulus to 110.6 (47.9), without affecting the signal intensity of normal annulus (p = 0.14). Mean (SD) CNR between the diseased and normal annulus increased (p < 0.001) from 11.8 (14.1) to 29.6 (29.1). Both masked readers detected more annular fissures after processing in IVDs with Pfirrmann grade of ≤ 2 and > 2, with an apparent increased sensitivity and decreased specificity using predefined image-based human categorization as a reference standard.ConclusionsImage processing improved CNR of annular fissures and detection rate of annular fissures. However, further studies with a more stringent reference standard are needed to assess its effect on sensitivity and specificity.© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.