• Clinical biomechanics · Dec 2019

    Locking plate constructs benefit from interfragmentary lag screw fixation with decreased shear movements and more predictable fracture gap motion in simple fracture patterns.

    • Sven Märdian, Werner Schmölz, Klaus-Dieter Schaser, Georg N Duda, and Mark Heyland.
    • Centre for Musculoskeletal Surgery, Charité-Universitätsmedizin Berlin, Augustenburger Platz 1, 13353 Berlin, Germany. Electronic address: sven.maerdian@charite.de.
    • Clin Biomech (Bristol, Avon). 2019 Dec 1; 70: 89-96.

    BackgroundA mechanical characterisation of lag screw fixation plus locking plate - although clinically widely used as either "mixed fixation concept" or absolutely stable fixation - is so far missing. This study aimed to evaluate the influence of an interfragmentary lag screw on the resulting motion at the fracture site of locking plate constructs using a simple fracture at the distal femur.MethodsHuman cadaver femora were in vitro loaded in torsion and axial bending-compression with and without lag screw fixation next to a locking plate fixation. In addition, two plate working lengths were tested. Interfragmentary movement was measured optically.FindingsAxial interfragmentary movement is reduced with lag screw (102 mm plate working length, 1000 N, mean): 0.28 mm versus 0.82 mm. With lag screw, the fracture gap stays closed with mean normal interfragmentary movement ≤0.03 mm. Fracture gap tends to open without lag screw: normal interfragmentary movement up to -0.29 mm. Reduction of shear interfragmentary movement was observed throughout all tested loads and groups. Mean true shear remains generally low with lag screw (≤0.42 mm) compared to without lag screw (≤1.46 mm). We also found that interfragmentary movement variance decreases with lag screw, especially for longer plate working length.InterpretationAn interfragmentary lag screw next to locking bridge plating reduces fragment motion in vitro for a simple fracture pattern and provides a sufficient tool to decrease detrimental shear movements. Prospective clinical trials with interfragmentary lag screw fixation should prove these findings in wide clinical use to treat simple fracture patterns.Copyright © 2019 Elsevier Ltd. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…