-
- Foster R Goss, Li Zhou, and Scott G Weiner.
- University of Colorado, Department of Emergency Medicine, Aurora, CO, United States; Tufts Medical Center, Department of Emergency Medicine and Clinical Decision Making, Boston, MA, United States. Electronic address: Foster.Goss@ucdenver.edu.
- Int J Med Inform. 2016 Sep 1; 93: 70-3.
BackgroundPhysician use of computerized speech recognition (SR) technology has risen in recent years due to its ease of use and efficiency at the point of care. However, error rates between 10 and 23% have been observed, raising concern about the number of errors being entered into the permanent medical record, their impact on quality of care and medical liability that may arise. Our aim was to determine the incidence and types of SR errors introduced by this technology in the emergency department (ED).SettingLevel 1 emergency department with 42,000 visits/year in a tertiary academic teaching hospital.MethodsA random sample of 100 notes dictated by attending emergency physicians (EPs) using SR software was collected from the ED electronic health record between January and June 2012. Two board-certified EPs annotated the notes and conducted error analysis independently. An existing classification schema was adopted to classify errors into eight errors types. Critical errors deemed to potentially impact patient care were identified.ResultsThere were 128 errors in total or 1.3 errors per note, and 14.8% (n=19) errors were judged to be critical. 71% of notes contained errors, and 15% contained one or more critical errors. Annunciation errors were the highest at 53.9% (n=69), followed by deletions at 18.0% (n=23) and added words at 11.7% (n=15). Nonsense errors, homonyms and spelling errors were present in 10.9% (n=14), 4.7% (n=6), and 0.8% (n=1) of notes, respectively. There were no suffix or dictionary errors. Inter-annotator agreement was 97.8%.ConclusionsThis is the first estimate at classifying speech recognition errors in dictated emergency department notes. Speech recognition errors occur commonly with annunciation errors being the most frequent. Error rates were comparable if not lower than previous studies. 15% of errors were deemed critical, potentially leading to miscommunication that could affect patient care.Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.