• J. Endovasc. Ther. · Feb 2010

    Comparative Study

    Application of the Willis covered stent in the treatment of aneurysm in the cisternal segment of the internal carotid artery: a pilot comparative study with midterm follow-up.

    • Yue-Qi Zhu, Ming-Hua Li, Chun Fang, Hua-Qiao Tan, Wu Wang, Pei-Lei Zhang, Ying-Sheng Cheng, Jian-Bo Wang, and Lian-Ting Ma.
    • Department of Diagnostic and Interventional Radiology, The Sixth Affiliated People's Hospital, Medical School of Shanghai Jiao Tong University, Shanghai, China.
    • J. Endovasc. Ther. 2010 Feb 1; 17 (1): 55-65.

    PurposeTo compare the use of the Willis stent-graft versus coil embolization for complicated aneurysms in the cisternal segment of the internal carotid artery (ICA).MethodsThirty-four patients (19 women; mean age 46.7+/-16.8 years, range 3-79) with 36 complicated aneurysms were treated either by Willis covered stents (n = 19) or by coil embolization (n = 17). Follow-up angiography was performed to investigate aneurysm recurrence, endoleak, and parent artery stenosis. Kaplan-Meier curves were constructed to compare the freedom from recurrence and parent artery stenosis rates in both groups. Clinical follow-up data were retrospectively analyzed and categorized as fully recovered, improved, unchanged, or worsened.ResultsIn the covered stent group, total exclusion was immediately achieved in 13 aneurysms; there were 5 minor endoleaks and 1 delivery failure. In the patients treated with coil embolization, total/near-total occlusion was achieved in 7 aneurysms, subtotal in 8, and partial in 2. Acute thrombosis occurred in 1 patient in each group, while 1 patient experienced recurrent hemorrhage after embolotherapy. Follow-up angiography (mean 14.3+/-9.4, range 3-31) revealed that 16 aneurysms were completely isolated in the stent-graft group, with only 2 mild in-stent stenoses. Eighteen months after the procedure, Kaplan-Meier analysis showed recurrence-free rates of 93.3% and 50% for the stent-graft versus coil groups, respectively; freedom from parent artery stenosis was 87.5% and 100%. Symptoms were fully eliminated in 9 patients in each group; they were improved in 3 and 5, unchanged in 2 and 2, and worsened in 1 and 0, respectively, at the end of the follow-up period.ConclusionWillis stent-graft application is an alternative to treat complicated aneurysms in the cisternal segment of the ICA. In the case of a tortuous parent artery or potential side branch coverage, however, it is still not a first choice therapy.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…