• Plos One · Jan 2018

    Viable adhered Staphylococcus aureus highly reduced on novel antimicrobial sutures using chlorhexidine and octenidine to avoid surgical site infection (SSI).

    • Andreas Obermeier, Jochen Schneider, Norbert Harrasser, Jutta Tübel, Heinrich Mühlhofer, Dominik Pförringer, Deimling Constantin von CV Klinik für Orthopädie und Sportorthopädie, Klinikum rechts der Isar der Technischen Universität München, München, Germany., Peter Foehr, Barbara Kiefel, Christina Krämer, Axel Stemberger, Matthias Schieker, Rainer Burgkart, and Rüdiger von Eisenhart-Rothe.
    • Klinik für Orthopädie und Sportorthopädie, Klinikum rechts der Isar der Technischen Universität München, München, Germany.
    • Plos One. 2018 Jan 1; 13 (1): e0190912.

    BackgroundSurgical sutures can promote migration of bacteria and thus start infections. Antiseptic coating of sutures may inhibit proliferation of adhered bacteria and avoid such complications.ObjectivesThis study investigated the inhibition of viable adhering bacteria on novel antimicrobially coated surgical sutures using chlorhexidine or octenidine, a critical factor for proliferation at the onset of local infections. The medical need, a rapid eradication of bacteria in wounds, can be fulfilled by a high antimicrobial efficacy during the first days after wound closure.MethodsAs a pretesting on antibacterial efficacy against relevant bacterial pathogens a zone of inhibition assay was conducted with middle ranged concentrated suture coatings (22 μg/cm). For further investigation of adhering bacteria in detail the most clinically relevant Staphylococcus aureus (ATCC®49230™) was used. Absorbable braided sutures were coated with chlorhexidine-laurate, chlorhexidine-palmitate, octenidine-laurate, and octenidine-palmitate. Each coating type resulted in 11, 22, or 33 μg/cm drug content on sutures. Scanning electron microscopy (SEM) was performed once to inspect the coating quality and twice to investigate if bacteria have colonized on sutures. Adhesion experiments were assessed by exposing coated sutures to S. aureus suspensions for 3 h at 37°C. Subsequently, sutures were sonicated and the number of viable bacteria released from the suture surface was determined. Furthermore, the number of viable planktonic bacteria was measured in suspensions containing antimicrobial sutures. Commercially available sutures without drugs (Vicryl®, PGA Resorba®, and Gunze PGA), as well as triclosan-containing Vicryl® Plus were used as control groups.ResultsZone of inhibition assay documented a multispecies efficacy of novel coated sutures against tested bacterial strains, comparable to most relevant S. aureus over 48 hours. SEM pictures demonstrated uniform layers on coated sutures with higher roughness for palmitate coatings and sustaining integrity of coated sutures. Adherent S. aureus were found via SEM on all types of investigated sutures. The novel antimicrobial sutures showed significantly less viable adhered S. aureus bacteria (up to 6.1 log) compared to Vicryl® Plus (0.5 log). Within 11 μg/cm drug-containing sutures, octenidine-palmitate (OL11) showed the highest number of viable adhered S. aureus (0.5 log), similar to Vicryl® Plus. Chlorhexidine-laurate (CL11) showed the lowest number of S. aureus on sutures (1.7 log), a 1.2 log greater reduction. In addition, planktonic S. aureus in suspensions were highly inhibited by CL11 (0.9 log) represents a 0.6 log greater reduction compared to Vicryl® Plus (0.3 log).ConclusionsNovel antimicrobial sutures can potentially limit surgical site infections caused by multiple pathogenic bacterial species. Therefore, a potential inhibition of multispecies biofilm formation is assumed. In detail tested with S. aureus, the chlorhexidine-laurate coating (CL11) best meets the medical requirements for a fast bacterial eradication. This suture coating shows the lowest survival rate of adhering as well as planktonic bacteria, a high drug release during the first-clinically most relevant- 48 hours, as well as biocompatibility. Thus, CL11 coatings should be recommended for prophylactic antimicrobial sutures as an optimal surgical supplement to reduce wound infections. However, animal and clinical investigations are important to prove safety and efficacy for future applications.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.