• J Clin Orthop Trauma · Nov 2020

    Review

    Anatomical quadrilateral plate for acetabulum fractures involving quadrilateral surface: A review.

    • Ramesh K Sen, Gaurav Saini, Sagar Kadam, and Neha Raman.
    • Institute of Orthopaedics, Max Hospital, 5439,38 West Chandigarh, Mohali, 160014, Punjab, India.
    • J Clin Orthop Trauma. 2020 Nov 1; 11 (6): 1072-1081.

    IntroductionThe management of acetabulum fractures in osteoporotic elderly, as well as comminuted fractures in younger patients is likely to be difficult. These fractures need specific fixation techniques especially when the quadrilateral plate is involved. Standard implants may not be able to adequately support the fixation, so newer pre-shaped fixation plates have been proposed with some of these already in use. The concept of anatomic plates has come up for many fracture locations for providing a better buttress effect to the comminuted fragments. There has been a need to look for an anatomic buttress plates being developed for acetabulum fractures involving the quadrilateral surface.Materials And MethodsThe literature has been reviewed to find the various newer designs that have been used for buttressing the quadrilateral surface in comminuted acetabular fractures. An attempt has been made to study their design characteristics and clinical outcomes. The review also includes the analysis of Anatomic Quadrilateral plate (AQP) used in fixation of acetabulum fracture involving quadrilateral surface in a series of 33 patients.ResultsThere has been few anatomical plates developed for the stabilization of acetabular quadrilateral surface fractures. Some of these plates have been successfully used in management of acetabular fractures primarily in young patients. Issues however remain in their application and outcomes in osteoporotic fractures of the acetabulum, as these plates support the pelvic brim fragments either from superior or medial surface. The newer development i.e. 'Anatomical Quadrilateral Plate' is optimized to counter the displacement forces due to its positioning on the pelvic brim rather than its superior or medial surface. Other special features include the possibility of longer screws across bone due to oblique position of holes, the typical location of a locking hole on the plate beam which permits dual cortical compression fixation either by using a bigger screw or a specially designed screw in screw construct across the supra-acetabular corridor. The option of using hybrid fixation of both locking and unlocked screws in AQP allows proper stress distribution on the underlying bone, aiding both primary as well as secondary stability. The minimum of one year post surgery outcome of patients having acetabular fixation using this Anatomic quadrilateral plate has been analyzed in 33 patients. Twenty three of these were aged more than 50 years and 28 out of total 33 were males. Associated injuries included Ipsilateral lower limb injury in 2 patients and distal radius fracture in 5 patients. The fracture pattern included 'Anterior column posterior hemi-transverse' in 10 patients,' Associated Both Column' injury in 9 and 'T type' acetabular fractures in 8 patients. Isolated 'Anterior column' was fractured in 6 patients. The surgical approach was 'Anterior Intra-pelvic' (AIP) in 23 patients and 'Modified Ileo-femoral' in other 10 patients. One patient had additional K L approach. Among the implants, the AQP plate was used without its pubic arm in 6 patients. The post-operative x rays showed anatomical reduction in 28 patients, while other 5 had gaps and/or steps up to 2 mm size. In subsequent car, one of these patients needed hip arthroplasty for problem arising due to collapse in fixation within six months. EQ 5D 5L telephonic score was used to know the outcome at minimum of one year follow up in 33 patients. As per this score, only 3 patients had an issue with mobility, with only one having problem in self-care activity. Six patients complained of minor limitations in carrying out their usual activities and only one patient had anxiety affecting him. In their self-assessment of overall health status, 22 patients marked it 100, 7 made it 90, 3 as 80 and 1 had marked it as 70 in a score range of 0-100. Considering the predominant elderly profile in this series of patients, the acetabular reconstruction using 'Anatomic quadrilateral plate' has shown encouraging results.ConclusionFor stabilization of acetabular fractures involving quadrilateral surface area and pelvic brim, various new implants have been used. The Anatomic quadrilateral plate due to its anatomical shape, the various options in fracture fixation is best optimized for management of comminuted acetabulum fractures especially in poor quality bones. It has been successful in achieving good outcome in elderly group of patients having these complex injuries.© 2020 Delhi Orthopedic Association. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.