• J Arthroplasty · Sep 2019

    Subsidence of Hydroxyapatite-Coated Femoral Stem in Dorr Type C Proximal Femoral Morphology.

    • Piti Rattanaprichavej, Artit Laoruengthana, Thanainit Chotanaphuti, Saradej Khuangsirikul, Chanadol Phreethanutt, and Krit Pongpirul.
    • Department of Orthopaedics, Faculty of Medicine, Naresuan University, Phitsanulok, Thailand.
    • J Arthroplasty. 2019 Sep 1; 34 (9): 2011-2015.

    BackgroundGood bone quality and proper proximal femoral morphology are thought to be necessary for tapered design, cementless femoral stems to resist subsidence. Using tapered, cementless stem for patients with stovepipe morphology or Dorr type C is controversial. The purpose of this study is to analyze (1) subsidence of the fully hydroxyapatite (HA)-coated, tapered, cementless stem in different morphology according to Dorr classification, (2) subsidence of the stem related to radiographic canal-fill ratio.MethodsThe digitized radiographs of 311 consecutive cementless primary total hip arthroplasty with fully HA-coated, tapered stem were retrospectively reviewed. Subsidence and the canal-fill ratio at 4 locations were evaluated postoperatively after a minimum of 2 years of follow-up. The threshold of subsidence >3 mm was considered as a clinically significant migration.ResultsA multivariate regression analysis of subsidence across Dorr type, controlling for age, gender, and intraoperative calcar fracture, demonstrated 0.40 mm (P = .28) and 0.18 mm (P = .51) greater subsidence in Dorr type C and B when compared to Dorr type A. Age, gender, and calcar fracture had no influence on subsidence, whereas greater canal-fill ratio at 2 cm below lesser trochanter resulted in significantly less subsidence (P = .02). Additionally, all variables did not affect the risk of having subsidence >3 mm.ConclusionThe proximal femoral morphology has no statistically significant effect on the subsidence of fully HA-coated stem. Therefore, this stem type might be a viable option for Dorr type C. Increasing the canal-fill ratio at metadiaphyseal junction may ensure the stability of the stem.Copyright © 2019 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…