BackgroundDetection of procedural thromboembolism by diffusion-weighted magnetic resonance imaging (MR-DWI+) can help identify and mitigate endovascular risk factors. Data remain scant on procedural MR-DWI+ following the use of the Neuroform open-cell design stent in aneurysm embolization.ObjectiveWe sought to evaluate the incidence of MR-DWI+ in Neuroform simple and multi-stent construct stenting for intracranial aneurysms in an attempt to delineate baseline risk and identify possible associated procedural factors.MethodsSeventy-six patients receiving 97 Neuroform stents in the treatment of intracranial aneurysm were identified from a prospective database and eligible for inclusion in the study. Diffusion-weighted magnetic resonance imaging (MR-DWI) was obtained in all patients within 48 hours of the procedure and reviewed for the presence of MR-DWI+ with patient records reviewed for analysis of factors predisposing to these lesions.ResultsPatients were treated with single-stent Neuroform constructs in 57 cases (73%) and multi-stent Neuroform constructs in 21 cases (27%). Y-stent technique was used in 16 cases. MR-DWI+ was identified in 7 of 78 cases (9.0%), with MR-DWI+ in 0 of 10 subarachnoid hemorrhage cases. No MR-DWI lesions led to a permanent neurological deficit at discharge. There was no MR-DWI+ in patients treated with Y-stenting or multi-stent Neuroform constructs. The only factor associated with ipsilateral MR-DWI+ was target aneurysm location on an arterial sidewall over bifurcation (P = .01).ConclusionThe Neuroform stent carries a very low risk of MR-DWI+ compared with its closed-cell design counterpart. Subarachnoid hemorrhage and deployment of multiple stents in the same anatomical region in configurations such as the Y-stent construct did not increase the risk of acute procedural thromboembolism.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.