• Abdom Radiol (NY) · Sep 2020

    CT-based liver surface nodularity for the detection of clinically significant portal hypertension: defining measurement quality criteria.

    • Riccardo Sartoris, Marie Lazareth, Arianna Nivolli, Marco Dioguardi Burgio, Valérie Vilgrain, and Maxime Ronot.
    • Assistance Publique - Hôpitaux de Paris, Hôpitaux Universitaires Paris Nord Val de Seine, Hôpital Beaujon, 100 boulevard du Général Leclerc, 92110, Clichy, France.
    • Abdom Radiol (NY). 2020 Sep 1; 45 (9): 2755-2763.

    PurposeTo establish measurement quality criteria for the noninvasive assessment of clinically significant portal hypertension (CSPH) in patients with cirrhosis using CT-based liver surface nodularity (LSN) measurements.MethodsSeventy-four consecutive patients with cirrhosis (mean 62 ± 13 years), including 30 with CSPH (41%), underwent CT and hepatic venous pressure gradient measurements. Three independent readers performed 15 LSN measurements/patient using dedicated software. LSN was computed based on the median and means of one to 15 measurements. Accuracy for diagnosing CSPH was assessed using receiver operating characteristic (ROC) curve analysis. Variability was assessed by the intra-class correlation coefficient (ICC) and the Bland-Altman plot (BA). Quality criteria were identified to maximize the accuracy of LSN and minimize variability.ResultsThe area under the (AU) ROCs of mean and median LSN measurements based on one to 15 measurements ranged from 0.79 ± 0.05 to 0.91 ± 0.04 and 0.86 ± 0.04 to 0.91 ± 0.03, respectively, with no difference on pair-wise comparisons (all p > 0.05). AUROCs of LSN increased from one to eight and leveled off between eight and 15 measurements. Inter- and intra-reader variability decreased from one to 15 measurements, with only slight improvement after more than eight measurements. Intra- and inter-observer agreements were excellent with eight measurements (ICC = 0.90 [95%CI 0.84-0.94], and ICC = 0.93 [95%CI 0.89-0.95], respectively), and variability for intra-observer and inter-observer agreement was low (BA bias 4.2% (95% limits of agreement [LoA] [- 15.3; + 23.7%]) and 4.8% LoA [ - 17.5; + 27.1%], respectively).ConclusionsCT-based LSN measurement is highly reproducible and accurate. We suggest using at least 8 valid measurements to determine the mean LSN value for the detection of CSPH.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.