- Bino A Varghese, Darryl Hwang, Steven Y Cen, Joshua Levy, Derek Liu, Christopher Lau, Marielena Rivas, Bhushan Desai, David J Goodenough, and Vinay A Duddalwar.
- Dept. of Radiology, Univ. of Southern California, Los Angeles, CA, USA.
- J Appl Clin Med Phys. 2019 Aug 1; 20 (8): 155-163.
ObjectiveTo determine the intra-, inter- and test-retest variability of CT-based texture analysis (CTTA) metrics.Materials And MethodsIn this study, we conducted a series of CT imaging experiments using a texture phantom to evaluate the performance of a CTTA panel on routine abdominal imaging protocols. The phantom comprises of three different regions with various textures found in tumors. The phantom was scanned on two CT scanners viz. the Philips Brilliance 64 CT and Toshiba Aquilion Prime 160 CT scanners. The intra-scanner variability of the CTTA metrics was evaluated across imaging parameters such as slice thickness, field of view, post-reconstruction filtering, tube voltage, and tube current. For each scanner and scanning parameter combination, we evaluated the performance of eight different types of texture quantification techniques on a predetermined region of interest (ROI) within the phantom image using 235 different texture metrics. We conducted the repeatability (test-retest) and robustness (intra-scanner) test on both the scanners and the reproducibility test was conducted by comparing the inter-scanner differences in the repeatability and robustness to identify reliable CTTA metrics. Reliable metrics are those metrics that are repeatable, reproducible and robust.ResultsAs expected, the robustness, repeatability and reproducibility of CTTA metrics are variably sensitive to various scanner and scanning parameters. Entropy of Fast Fourier Transform-based texture metrics was overall most reliable across the two scanners and scanning conditions. Post-processing techniques that reduce image noise while preserving the underlying edges associated with true anatomy or pathology bring about significant differences in radiomic reliability compared to when they were not used.ConclusionFollowing large-scale validation, identification of reliable CTTA metrics can aid in conducting large-scale multicenter CTTA analysis using sample sets acquired using different imaging protocols, scanners etc.© 2019 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.