• J Neurosurg Spine · Jan 2020

    Biomechanical evaluation of two alternative techniques to the Goel-Harms technique for atlantoaxial fixation: C1 lateral mass-C2 bicortical translaminar screw fixation and C1 lateral mass-C2/3 transarticular screw fixation.

    • Yue-Qi Du, Teng Li, Chao Ma, Guang-Yu Qiao, Yi-Heng Yin, and Xin-Guang Yu.
    • 1Department of Neurosurgery, Chinese PLA General Hospital, Beijing; and.
    • J Neurosurg Spine. 2020 Jan 17: 1-7.

    ObjectiveThe authors conducted a study to investigate the biomechanical feasibility and stability of C1 lateral mass-C2 bicortical translaminar screw (C1LM-C2TL) fixation, C1 lateral mass-C2/3 transarticular screw (C1LM-C2/3TA) fixation, and C1LM-C2/3TA fixation with transverse cross-links (C1LM-C2/3TACL) as alternative techniques to the Goel-Harms technique (C1 lateral mass-C2 pedicle screw [C1LM-C2PS] fixation) for atlantoaxial fixation.MethodsEight human cadaveric cervical spines (occiput-C7) were tested using an industrial robot. Pure moments that were a maximum of 1.5 Nm were applied in flexion-extension (FE), lateral bending (LB), and axial rotation (AR). The specimens were first tested in the intact state and followed by destabilization (a type II odontoid fracture) and fixation as follows: C1LM-C2PS, C1LM-C2TL, C1LM-C2/3TA, and C1LM-C2/3TACL. For each condition, the authors evaluated the range of motion and neutral zone across C1 and C2 in all directions.ResultsCompared with the intact spine, each instrumented spine significantly increased in stability at the C1-2 segment. C1LM-C2TL fixation demonstrated similar stability in FE and LB and greater stability in AR than C1LM-C2PS fixation. C1LM-C2/3TA fixation was equivalent in LB and superior in FE to those of C1LM-C2PS and C1LM-C2TL fixation. During AR, the C1LM-C2/3TA-instrumented spine failed to maintain segmental stability. After adding a cross-link, the rotational stability was significantly increased in the C1LM-C2/3TACL-instrumented spine compared with the C1LM-C2/3TA-instrumented spine. Although inferior to C1LM-C2TL fixation, the C1LM-C2/3TACL-instrumented spine showed equivalent rotational stability to the C1LM-C2PS-instrumented spine.ConclusionsOn the basis of our biomechanical study, C1LM-C2TL and C1LM-C2/3TACL fixation resulted in satisfactory atlantoaxial stabilization compared with C1LM-C2PS. Therefore, the authors believe that the C1LM-C2TL and C1LM-C2/3TACL fixation may serve as alternative procedures when the Goel-Harms technique (C1LM-C2PS) is not feasible due to anatomical constraints.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…