-
Randomized Controlled Trial Clinical Trial
New device technologies for subcutaneous fat biopsy.
- Lawrence G Kettwich, Wilmer L Sibbitt, N Suzanne Emil, Usman Ashraf, Leslie Sanchez-Goettler, Yumna Thariani, and Arthur D Bankhurst.
- School of Medicine, Division of Rheumatology, University of New Mexico Health Sciences Center, Albuquerque, USA.
- Amyloid. 2012 Jun 1; 19 (2): 66-73.
PurposeSubcutaneous fat biopsy is useful for the evaluation of amyloidosis, environmental contaminants, lipid metabolism, genetic studies and diabetes research. The present study examined new technologies for fat biopsy.MethodsSubcutaneous fat biopsy in 10 high-risk individuals was randomized to (i) a 10 ml reciprocating procedure device (RPD) mechanical syringe or (ii) a 60 ml vacuum syringe. Outcome measures included pain by the 10 cm Visual Analogue Pain Scale (VAS), adequacy of biopsied tissue, complications and diagnosis. The operator's ability to control syringes was quantitatively measured by the linear displacement method.ResultsBoth syringes permitted facile aspiration of subcutaneous fat with adequate sample without complications. The mechanical and the vacuum syringes enhanced control of the needle compared to conventional syringes, reducing unintended forward penetration by 75% (3.6 ± 0.5 mm) and 87% (12.0 ± 1.4 mm), respectively (p < 0.0001). Free adipose cells were obtained in abundance as well as columnar biopsies containing intact blood vessels and connective tissue septa permitting precise microhistological examination. One case of primary AL amyloidosis (κ light chain disease) was diagnosed in each group.ConclusionsSubcutaneous fat biopsy by needle aspiration can be facilely achieved with new aspiration syringe technologies with improved needle control and enhanced patient safety.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.