-
- Shee Young Hahm, Suk Jung Choo, Jae Won Lee, Joon Beom Seo, Tae Hwan Lim, Jae Kwan Song, Je Kyoun Shin, and Meong Gun Song.
- Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, University of Ulsan, Seoul, Republic of Korea.
- Eur J Cardiothorac Surg. 2006 Apr 1; 29 (4): 530-6.
ObjectiveThe present study was aimed to assess the results of newly developed aortic valve repair technique.MethodsBetween 1997 and 2004, 69 aortic valvuloplasties were performed with a new technique addressing the three main components of the aortic root; leaflets (L), sinotubular junction (STJ), and aortic annulus (A). For leaflet correction, additional leaflets were implanted and for STJ and annular reduction, an internal synthetic ring and strip along the fibrous annulus were implanted, respectively. The patients were divided into two groups: 30 patients with isolated aortic regurgitation (group IAR) were treated by correction of STJ+L (n=21) and STJ+A+L (n=9), and 39 aortic regurgitation patients with annuloaortic ectasia or ascending aortic aneurysm (group AAR) were treated with STJ correction only (n=16), STJ+A (n=6), STJ+L (n=9), and STJ+A+L (n=8).ResultsThe mean age was 43.4 and 49.5 years for groups IAR and AAR, respectively. There was neither operative nor follow-up death in either group. Suture breakage caused one reoperation in group IAR. Mean follow-up was 13.8 and 20.3 months in groups IAR and AAR, respectively. The preoperative aortic regurgitation grade was 3.67 in group IAR and 2.67 in group AAR. The last follow-up aortic regurgitation grade was 1.1 in group IAR and 1.05 in group AAR. No patient, except for the reoperated patient had AR greater than grade 2. The postoperative pressure gradient was 19.3 mmHg in group IAR and 8. 4mmHg in group AAR.ConclusionsThe results showed this technique to be safe and effective. Thus far broad application of this repair technique has been demonstrated to be highly feasible.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.