• Plos One · Jan 2018

    Quantitative analysis of pupillometry in isolated third nerve palsy.

    • Hyeong Min Kim, Hee Kyung Yang, and Jeong-Min Hwang.
    • Department of Ophthalmology, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam, Korea.
    • Plos One. 2018 Jan 1; 13 (11): e0208259.

    ObjectivesTo objectively assess pupillary involvement according to various etiologies of acquired isolated third nerve palsy using automated pupillometry, and evaluate the efficacy of digital pupillometry in discriminating compressive lesions from microvascular ischemic third nerve palsy.DesignRetrospective, observational case series.MethodsA total of 171 subjects were included in this study, consisting of 60 subjects with presumed microvascular ischemic third nerve palsy, 51 with non-ischemic third nerve palsy, and 60 controls whose pupillary light responses were measured using a dynamic automated pupillometer. Subjects with non-ischemic third nerve palsy were divided into subgroups according to their etiology; inflammatory and compressive groups including tumor and aneurysm. Pupillometry parameters including minimum and maximum pupil diameters, constriction latency and ratio, maximum and average constriction velocities and dilation velocity were noted. The diagnostic ability of pupillometry parameters for discriminating compressive vs microvascular ischemic third nerve palsy was evaluated. The inter-eye difference of the involved eye and the uninvolved fellow eye was calculated to adjust for individual variability.ResultsAmong all parameters, reduced pupillary constriction ratio was the most specific parameter for detecting non-ischemic third nerve palsy, as a large inter-eye difference beyond the normative range of controls was found in 0% of ischemic, 20% of inflammatory and 60% of compressive third nerve palsy. With the diagnostic criteria using inter-eye differences of 1) minimum pupil diameter > 0.45 mm, or 2) pupillary constriction ratio < -7.5% compared to the fellow eye, the sensitivity and specificity for diagnosing compressive third nerve palsy were 95% and 88%, respectively. In the compressive group, positive correlations were found between the degree of external ophthalmoplegia and constriction ratio (r = 0.615, p<0.001), average constriction velocity (r = 0.591, p = 0.001) and maximum constriction velocity (r = 0.582, p = 0.001).ConclusionsAbnormal pupillary constriction ratio was highly specific for detecting compressive third nerve palsy, although the sensitivity was not high. Digital pupillometry demonstrated relatively good performance for discriminating compressive lesions from microvascular ischemic third nerve palsy.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.