Journal of biomechanics · Jan 2021
Biomechanical evaluation of the docking nail concept in periprosthetic fracture fixation around a stemmed total knee arthroplasty.
- Mark Lenz, Yves Pascal Acklin, Lena Anna Kasper, Dominic Mischler, Peter Varga, Ivan Zderic, Dominic Gehweiler, Kajetan Klos, Boyko Gueorguiev, and Karl Stoffel.
- AO Research Institute Davos, Switzerland; Department of Trauma, Hand and Reconstructive Surgery, University Hospital Jena, Germany. Electronic address: lenzmar@web.de.
- J Biomech. 2021 Jan 22; 115: 110109.
AbstractIntramedullary femoral nails provide an ideal mechanical axis for periprosthetic fracture fixation. Slotted nails allow a connection to a total knee arthroplasty (TKA) stem. This study aims to compare implant and construct stiffness, interfragmentary movement and cycles to failure between an antegrade slotted femoral nail construct docked to a TKA stem and a distal femoral locking plate in a human periprosthetic femoral fracture model. In eight pairs of fresh-frozen human femora with stalked TKA, a 10 mm transverse osteotomy gap was set simulating a Rorabeck type II, Su type I fracture. The femora were pairwise instrumented with either an antegrade slotted nail coupled to the prosthesis stem, or a locking plate. Cyclic testing with a progressively increasing physiologic loading profile was performed at 2 Hz until catastrophic construct failure. Relative movement at the osteotomy site was monitored by means of optical motion tracking. In addition, four-point bending implant stiffness, torsional implant stiffness and frictional fit of the stem-nail connection were investigated via separate non-destructive tests. Intramedullary nails exhibited significantly higher four-point bending and significantly lower torsional implant stiffness than plates, P < 0.01. Increasing difference between nail and stem diameters decreased frictional fit at the stem-nail junction. Nail constructs provided significantly higher initial axial bending stiffness and cycles to failure (200 ± 83 N/mm; 16'871 ± 5'227) compared to plate constructs (93 ± 35 N/mm; 7'562 ± 1'064), P = 0.01. Relative axial translation at osteotomy level after 2'500 cycles was significantly smaller for nail fixation (0.14 ± 0.11 mm) compared with plate fixation (0.99 ± 0.20 mm), P < 0.01. From a biomechanical perspective, the docking nail concept offers higher initial and secondary stability under dynamic axial loading versus plating in TKA periprosthetic fracture fixation.Copyright © 2020. Published by Elsevier Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.