• J Hand Surg Eur Vol · Sep 2011

    Displaced unstable transverse fractures of the shaft of the proximal phalanx of the fingers in industrial workers: reduction and K-wire fixation leaving the metacarpophalangeal and proximal interphalangeal joints free.

    • Mohammad M Al-Qattan.
    • Department of Surgery, King Saud University, Riyadh, Saudi Arabia. moqattan@hotmail.com
    • J Hand Surg Eur Vol. 2011 Sep 1; 36 (7): 577-83.

    AbstractA series of 35 adult male industrial workers with displaced unstable transverse fractures of the shaft of the proximal phalanx of the fingers were treated with reduction and K-wire fixation leaving the metacarpophalangeal and interphalangeal joints free to move immediately after surgery. At final follow-up, the total active motion score of the injured finger was graded as excellent, good, fair, or poor if it was greater than 240°, 220-240°, 180-219°, or less than 180°, respectively. Complications were also documented. The results were compared with our previously published series of these fractures treated with two other techniques: percutaneous K-wires immobilizing the metacarpophalangeal joint and open reduction and interosseous loop wire fixation. The final TAM scores in the current study were excellent in 43%, good in 29%, fair in 14% and poor in 14%. Four out of the 35 patients (11%) had minor pin tract infection. These results were significantly better than the results following percutaneous K-wire fixation immobilizing the metacarpophalangeal joint indicating that immediate mobilization of all joints has a significant effect on the outcome.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…