• Neurosurgery · Mar 2012

    An optimized system for interventional magnetic resonance imaging-guided stereotactic surgery: preliminary evaluation of targeting accuracy.

    • Paul S Larson, Philip A Starr, Geoffrey Bates, Lisa Tansey, R Mark Richardson, and Alastair J Martin.
    • Department of Neurological Surgery, University of California, San Francisco, San Francisco, California 94143-0112, USA. larsonp@neurosurg.ucsf.edu
    • Neurosurgery. 2012 Mar 1;70(1 Suppl Operative):95-103; discussion 103.

    BackgroundDeep brain stimulation electrode placement with interventional magnetic resonance imaging (MRI) has previously been reported using a commercially available skull-mounted aiming device (Medtronic Nexframe MR) and native MRI scanner software. This first-generation method has technical limitations that are inherent to the hardware and software used. A novel system (SurgiVision ClearPoint) consisting of an aiming device (SMARTFrame) and software has been developed specifically for interventional MRI, including deep brain stimulation.ObjectiveTo report a series of phantom and cadaver tests performed to determine the capability, preliminary accuracy, and workflow of the system.MethodsEighteen experiments using a water phantom were used to determine the predictive accuracy of the software. Sixteen experiments using a gelatin-filled skull phantom were used to determine targeting accuracy of the aiming device. Six procedures in 3 cadaver heads were performed to compare the workflow and accuracy of ClearPoint with Nexframe MR.ResultsSoftware prediction experiments showed an average error of 0.9 ± 0.5 mm in magnitude in pitch and roll (mean pitch error, -0.2 ± 0.7 mm; mean roll error, 0.2 ± 0.7 mm) and an average error of 0.7 ± 0.3 mm in X-Y translation with a slight anterior (0.5 ± 0.3 mm) and lateral (0.4 ± 0.3 mm) bias. Targeting accuracy experiments showed an average radial error of 0.5 ± 0.3 mm. Cadaver experiments showed a radial error of 0.2 ± 0.1 mm with the ClearPoint system (average procedure time, 88 ± 14 minutes) vs 0.6 ± 0.2 mm with the Nexframe MR (average procedure time, 92 ± 12 minutes).ConclusionThis novel system provides the submillimetric accuracy required for stereotactic interventions, including deep brain stimulation placement. It also overcomes technical limitations inherent in the first-generation interventional MRI system.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…