-
- Jenny P Tsai, Julian Hardman, Nina Z Moore, M Shazam Hussain, Mark D Bain, Peter A Rasmussen, Thomas J Masaryk, Mohammed H Elgabaly, Lila Sheikhi, and Gabor Toth.
- Cerebrovascular Center, Cleveland Clinic, Cleveland, Ohio, USA.
- J Neurointerv Surg. 2019 Nov 1; 11 (11): 1141-1144.
IntroductionThe low-profile Neuroform Atlas stent received FDA Humanitarian Device Exemption status (HDE) in January 2018 for stent-assisted coil embolization of wide-necked saccular aneurysms. We review and report our results with the Atlas stent in our institution within the first year after its HDE approval.MethodsOur retrospective chart review identified patients treated with the Atlas stent. We analyzed the patient demographics, aneurysm characteristics, stent parameters and configuration, complications, angiographic, and clinical outcomes at discharge.ResultsFrom January to December 2018, 76 Atlas stents were deployed in 58 patients (average 1.3 stents/patient). Median patient age was 63.5 (IQR 56-71) years. Fifty-six (96.6%) patients had elective embolization of unruptured aneurysms, while two (3.4%) patients underwent embolization of a ruptured aneurysm within 2 weeks of subarachnoid hemorrhage. Forty (69.0%) patients were treated with a single stent, 15 (25.9%) with a Y-stent, and three (5.2%) with X-stent configuration. All stent deployments were technically successful. Most stents (82.9%) were the smallest 3 mm diameter devices. Procedural complications included transient stent-associated thrombosis in three (5.2%) patients and aneurysm rupture in one (1.7%). None had distal embolization, associated cerebral infarction, or permanent neurological deficits. Immediate Raymond-Roy 1 occlusion was achieved in 41 (70.7%) patients. Median hospital length of stay for elective aneurysm embolization was 1 day. Excellent outcomes with median National Institute of Health Stroke Scale score 0 (IQR 0-0) and modified Rankin Score 0 (IQR 0-1) were seen for elective patients at discharge.ConclusionThe Neuroform Atlas stent provided a reliable technical and safety profile for the treatment of intracranial wide-neck aneurysms. Further experience is needed to determine long-term durability and safety of this device.© Author(s) (or their employer(s)) 2019. No commercial re-use. See rights and permissions. Published by BMJ.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.