• J Orthop Trauma · Feb 2015

    Effect of distal interlocking screw number and position after intramedullary nailing of distal tibial fractures: a biomechanical study simulating immediate weight-bearing.

    • Daniel S Chan, Aniruddh N Nayak, Greg Blaisdell, Chris R James, Antony Denard, Jeremy Miles, and Brandon G Santoni.
    • *Orthopaedic Trauma Service, Tampa General Hospital, Tampa, FL; †Phillip Spiegel Orthopaedic Research Laboratory, Foundation for Orthopaedic Research and Education, Tampa, FL; and ‡Department of Orthopaedic Surgery and Sports Medicine, University of South Florida, Tampa, FL.
    • J Orthop Trauma. 2015 Feb 1; 29 (2): 98-104.

    ObjectiveTo quantify the changes in biomechanical stability conferred by the addition of a single medial blocking screw or a single bicortical interlocking screw to 2 existing distal points of screw fixation in a distal tibial fracture model repaired with intramedullary nailing.MethodsAfter simulation of a distal tibial metaphyseal fracture, 21 synthetic tibiae were repaired with an intramedullary nail and: (1) two bicortical locking screws placed in the 2 most distal screw holes (IM-L2); (2) three distal bicortical locking screws (IM-L3); and 2 distal locking screws and a single blocking screw positioned in the sagittal plane on the medial aspect of the nail (IM-L2B). The specimens were tested under combined cyclic axial and torsional loading for up to 16k cycles. The former was stepwise increasing, whereas the latter was with constant amplitude in internal rotation.ResultsAll constructs survived 12k cycles without hardware deformation or failure. IM-L3 constructs displayed the highest baseline axial stiffness at the beginning of the test (1130.9 ± 246.9 N/mm), which was significant compared with the IM-L2 construct (701.8 ± 189.57 N/mm, P = 0.004). No significant difference in baseline axial stiffness was identified between the IM-L3 and IM-L2B constructs (881.1 ± 182.4 N/mm, P = 0.125). Relative varus interfragmentary deformation at baseline was smaller in the IM-L3 treatment group (1.3 ± 0.3 degrees) relative to the IM-L2 group (2.4 ± 0.7 degrees, P = 0.012). No differences in torsional rigidity or relative interfragmentary torsional deformation were identified between groups (P > 0.168). Failure was breakage or backout of the distal bicortical screws, fracture of the distal fragment, or proximal screw breakage. There was no significant difference in number of cycles to failure between instrumentation groups (IM-L2: 14,345 ± 1438 cycles; IM-L3: 15,634 ± 626 cycles; and IM-L2B: 14,862 ± 1511 cycles, P = 0.184).ConclusionResults suggest that each of the constructs tested here may be a biomechanically viable option allowing for immediate weight-bearing after fixation of fractures of the distal third of the tibia. The addition of a single bicortical interlocking screw to create 3 points of distal fixation improves construct stiffness while reducing interfragmentary motion relative to 2 interlocking points of screw fixation with or without a blocking screw.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…