• Arch Orthop Trauma Surg · Mar 2013

    Cement augmentation of lag screws: an investigation on biomechanical advantages.

    • D Wähnert, L Hofmann-Fliri, K Schwieger, S Brianza, M J Raschke, and M Windolf.
    • AO Foundation, AO Research Institute, Clavadelerstrasse 8, Davos, Switzerland. dirk.waehnert@ukmuenster.de
    • Arch Orthop Trauma Surg. 2013 Mar 1;133(3):373-9.

    BackgroundIn trauma surgery, lag screws are commonly used. However, in osteoporotic bone, anchorage can be considerably compromised. This study investigates the biomechanical potential of cement augmentation in terms of improved fixation.Methods36 Surrogate osteoporotic bone specimens were utilised in three biomechanical experiments, each comparing 6 augmented with 6 non-augmented samples. Standard partially-threaded lag screws (Synthes) were placed following surgical standard. For the augmented groups, 0.4 ml of polymethylmethacrylate was injected into the pre-drilled hole prior to screw placement. Interfragmentary compression was determined using a cannulated ring compression sensor. Maximum torque was recorded with a torque wrench. Compressive relaxation after 24 h, relaxation after loosening and re-tightening the screw as well as maximum compression and torque at failure were measured.FindingsMean relaxation was significantly lower for the augmented group (p < 0.01). After 24 h, a remaining fragmental compression of 62 % for the augmented and 52 % for the non-augmented specimens was found. Loosening and re-tightening of the screw did not affect the compressive relaxation when augmentation was applied (p = 0.529), compared to an increased relaxation after re-tightening in the non-augmented group (p = 0.04). The mean maximum compression and torque until failure were significantly higher for the augmented group (p < 0.001).InterpretationCement augmentation of lag screws can improve fixation stability in terms of installing and maintaining interfragmentary compression. Effects of relaxation can be reduced and re-tightening of screws is possible without compromising the fixation. Particularly in reduced bone mass, augmentation of lag screws can markedly increase the security of the technique.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…