- Darren R Lebl, Frank P Cammisa, Federico P Girardi, Timothy Wright, and Celeste Abjornson.
- Hospital for Special Surgery, The Spine Care Institute, New York, NY 10021, USA. drlebl@alumni.stanford.edu
- Spine. 2012 Sep 1;37(19):E1209-17.
Study DesignA retrieval analysis of wear modes and fixation of lumbar total disc replacements (TDRs). Explanted Prodisc-L TDRs were prospectively collected during a 7-year period (2005-2011) and analyzed.ObjectiveTo assess the in vivo modes of wear and fixation of lumbar TDR with the Prodisc-L device.Summary Of Background DataInferior clinical outcomes and failure of lumbar TDR may occur because of suboptimal component fixation, wear properties, and impingement in a subset of patients. Posterior component TDR impingement has been demonstrated radiographically; however, despite its widespread use, the in vivo mechanical performance and fixation of the Prodisc-L device remain unknown.MethodsExplanted polyethylene and metallic (CoCrMo) components of Prodisc-L devices were examined by light stereo-microscopy (6X-31X), scanning electron microscopy, and energy-dispersive x-ray analysis from an international retrieval registry, with 13 participating surgeons.ResultsNineteen ProDisc-L devices from 18 patients (age, 44.7 ± 2.9 yr) following an index TDR at L4-L5 (n = 6), L5-S1 (n = 11), and unknown level (n = 2) were explanted for pain (n = 8), prosthesis subluxation/migration (n = 4), end plate collapse/subsidence (n = 3), polyethylene dislodgement (n = 3), and unknown (n = 2) after a mean length of implantation of 13.0 ± 3.9 months. Surface area of bony ongrowth was 9.6 ± 2.9% (range, 0%-52.5%). TDR burnishing was observed posteriorly consistent with component impingement in extension in 53% (8/15) (P < 0.02), more commonly than anterior 20% (3/15) lateral 20% (n = 3) (3/15) patterns. Circumferential burnishing was not observed. Posterior impingement was associated with 6° lordotic implants (P < 0.05) and 10-mm polyethylene size (P < 0.05). Backside wear occurred in 75% (9 of 12) of the disassembled implants and third-body wear was observed in 33% (5 of 15).ConclusionMetallic end plate burnishing was evident in a large percentage of clinically failed Prodisc-L TDR devices, most commonly posteriorly, consistent with impingement in extension. Long-term follow-up studies will evaluate the effects of the observed backside wear, third-body wear, and end plate impingement on clinical outcomes.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.