    BackgroundRobot-assisted thoracoscopic thymectomy has brought new challenges to the anaesthesiologists. Here we present a study of 17 patients undergoing robotic thymectomy.Patients And MethodsThe present study was a prospective study, which included 17 patients with myasthenia gravis scheduled for robot-assisted thoracoscopic thymectomy. Preoperatively, all scheduled medications were continued along with incentive spirometry.In the operating room, routine monitors were attached. Radial artery cannula and central venous catheter were inserted. Anaesthesia was induced with fentanyl, propofol and sevoflurane in oxygen and nitrous oxide. The neuromuscular blockade was achieved with atracurium. Airway was secured with double lumen tube. The capnography, entropy, neuromuscular junction and temperature monitoring were initiated. After patient positioning, one-lung ventilation was initiated prior to insertion of trocar. Thereafter, the robot was docked and surgery was started. During the surgical dissection, capnomediastinum was created. At the end of the surgery, double lumen tube was changed to single lumen endotracheal tube size. After extubation in ICU, continuous positive airway pressure of 5 mmHg was administered.ResultsIntraoperatively, all patients had transient episodes of arrhythmias and hypotension. The airway pressure increased from 23.7 +/- 2 to 28 +/- 2.7 cmH2O and central venous pressure increased from 12.9 +/- 1 to 19.2 +/- 1.6 mmHg after creation of capnomediastinum. The accidental rent in the right-sided pleura occurred in two patients. Intraoperatively, ventilatory difficulty was encountered in another two patients. One patient had brachial plexus injury. Two patients had hoarseness of voice.SummaryRefinement of the surgical technique is required to avoid compression by robotic arms on any portion of the patient, particularly the upper extremities. The use of beanbag for positioning of the ipsilateral arm needs to be evaluated further. The double lumen tube is to be positioned in such a way as to avoid any obstacle in the movement of robotic arm. We suggest pulse oximeter and arterial blood pressure monitoring in the abducted arm ipsilateral to the surgical approach. The airway pressure and capnography are to be monitored continuously for detection of capnothorax. Patient of robot-assisted thoracoscopic thymectomy should be observed for any nerve injury.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.