ObjectivesThe crucial decision to progress from pharmacological treatment of acute decompensated heart failure to institution of assist device or transplantation begins with evaluation of the chances for a successful recovery. We tested whether the intra-aortic balloon counterpulsation (IABP) could give us the necessary time for clinical decision-making and preserve adequate circulation until it is made.MethodsWe assessed 11 dilated cardiomyopathy patients of NYHA class IV, listed for heart transplantation or a ventricular assist device (VAD), who had conventional IABP placed. Heart function prior to and after IABP insertion as well as hemodynamics, end-organ function (renal and hepatic), frequency of complications and clinical outcomes were assessed.ResultsThe duration of intra-aortic balloon pump insertion ranged from 72 to 360 h (mean 181.54+/-81.65). After 48 h of intra-aortic balloon pump support, there was a significant increase of mean systemic arterial pressure from 74.5+/-9.6 to 82.3+/-4.7 mmHg (P=0.02), and ejection fraction from 14.7+/-6.4 to 21.0+/-8.6 (P=0.014). Meanwhile improvement of cardiac index, pulmonary wedge pressure and end-organ perfusion markers did not reach statistical significance. Three patients were successfully weaned off the balloon and recovered without additional interventions, two patients were transplanted and three were supported with counterpulsation until the implantation of assist device. Three patients died due to progressive heart failure, two after IABP removal and one after VAD implantation. There was no incidence of infection, limb ischemia, thrombus, or embolic complications.ConclusionsOur data showed that intra-aortic balloon pump support may be successfully and safely used in the acute decompensated dilated cardiomyopathy patients, as an urgent measure of cardiac support, to stabilize the patient and maintain organ perfusion until transplant is available, VAD is placed or patient is weaned from IABP.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.