Arch. Gynecol. Obstet. · Feb 2013
Clinical TrialLaparoscopic repair of vaginal vault prolapse by lateral suspension with mesh.
- Jean Dubuisson, Isabelle Eperon, Patrick Dällenbach, and Jean-Bernard Dubuisson.
- Perineology Unit, Division of Gynecology, Department of Obstetrics and Gynecology, University Hospitals of Geneva, 30 Boulevard de la Cluse, 1211, Geneva, Switzerland. neajdubuisson@yahoo.fr
- Arch. Gynecol. Obstet. 2013 Feb 1; 287 (2): 307-12.
BackgroundTo evaluate the long-term outcomes of laparoscopic lateral suspension using mesh reinforcement for symptomatic posthysterectomy vaginal vault prolapse.Materials And MethodsWe analyzed in a prospective cohort study all the women treated by laparoscopic lateral suspension with mesh for symptomatic vaginal vault prolapse between January 2004 and September 2010. In this procedure, the mesh is laterally suspended to the abdominal wall, posterior to the anterior superior iliac spine. We performed systematic follow-up examinations at 4 weeks, 6 months and yearly postoperatively. Clinical evaluation of pelvic organ support was assessed by the pelvic organ prolapse quantification (POP-Q) grading system. Main outcome measures were recurrence rate, reoperation rate for symptomatic recurrence or de novo prolapse, mesh erosion rate, reoperation rate for mesh erosion, total reoperation rate.Observations And ResultsOf the 73 patients seen at a mean 17.5 months follow-up, recurrent vaginal vault prolapse was registered in only one woman (success rate of 98.6 %). When considering all vaginal sites, we observed a total of 13 patients with recurrent or de novo prolapse (17.8 %). The non-previously treated posterior compartment was involved in eight cases (new appearance rate of 11 %). Of these 13 women, only 6 were symptomatic, requiring surgical management (reoperation rate for genital prolapse of 8.2 %). Four patients presented with mesh erosion into the vagina (5.5 %). Two required partial vaginal excision of the mesh in the operating room (2.7 %). There were no mesh-related infections. The total reoperation rate was 11 %.ConclusionLaparoscopic lateral suspension with mesh interposition is a safe and effective technique for the treatment of vaginal vault prolapse. This approach represents an alternative procedure to the laparoscopic sacrocolpopexy.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.