• Medicina · Mar 2021

    What We Should Consider in Point of Care Blood Glucose Test; Current Quality Management Status of a Single Institution.

    • Sooin Choi, Soo Jeong Choi, Byung Ryul Jeon, Yong-Wha Lee, Jongwon Oh, and You Kyoung Lee.
    • Department of Laboratory Medicine and Genetics, Soonchunhyang University College of Medicine, Soonchunhyang University Bucheon Hospital, 170 Jomaru-ro, Bucheon 14584, Korea.
    • Medicina (Kaunas). 2021 Mar 4; 57 (3).

    AbstractBackground and Objectives: Point of care test (POCT) is generally performed by non-laboratory staff who often lack an understanding on the quality control and quality assurance programs. The purpose of this study was to understand the current status of quality management of point of care (POC) blood glucose testing in a single institution where non-laboratory staff perform the tests. Materials and Methods: From July to August 2020, management status of glucometer, test strips, quality control (QC) materials, quality assurance program, and operators' response to processing of displayed results was monitored in all Soonchunhyang University Bucheon hospital departments that performed POC blood glucose test. Results of the POC blood glucose test conducted from January 2019 to May 2020 were analyzed retrospectively. Results: A total 124 glucometers were monitored in 47 departments. Insufficient management of approximately 50% of blood sugar, test strips, and QC materials was observed. Although daily QC was conducted by 95.7% of the departments, the QC records were inaccurate. The method of recording test results varied with departments and operators. Various judgments and troubleshooting were performed on the unexpected or out of measurable range results, including some inappropriate processes. In POC blood glucose test results review, 4568 atypical results were identified from a total of 572,207 results. Conclusions: Sufficient training of the non-laboratory staff and ongoing assessment of competency through recertification is needed to maintain acceptable levels of POCT quality. In this study, various problems were identified in glucometer and reagent management, QC and post-analytic phase. We believe that these results provide meaningful basal information for planning effective operators' training and competency evaluation, and the development of an efficient POCT quality management system.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…