-
Internal medicine journal · Oct 2017
Underuse of risk assessment and overuse of computed tomography pulmonary angiography in patients with suspected pulmonary thromboembolism.
- Michael Perera, Leena Aggarwal, Ian A Scott, and Nicholas Cocks.
- Department of General and Acute Medicine, Princess Alexandra Hospital, Brisbane, Queensland, Australia.
- Intern Med J. 2017 Oct 1; 47 (10): 1154-1160.
BackgroundEvidence suggests the potential overuse of computed tomography pulmonary angiography (CTPA) in patients with suspected pulmonary thromboembolism (PTE) in the absence of consistent use of pre-test clinical prediction rules and D-dimer assays.AimTo evaluate use and diagnostic utility of clinical prediction rules and D-dimer assay in patients with suspected PTE and quantify potentially avoidable overuse of CTPA in low risk patients.MethodsA total of 344 consecutive patients undergoing CTPA at a tertiary hospital was studied with regards to the use of D-dimer assays and clinical prediction rules for PTE. For each patient, a modified Wells score (mWS), revised Geneva score and PISA model were calculated retrospectively; performance characteristics for each rule for PTE were determined with reference to results of CTPA. Results for the mWS and D-dimer assays (when performed) were used to estimate the overuse of CTPA according to risk category.ResultsUse of a clinical prediction rule was documented in only 5.0% of cases. Of 269 low-risk patients who had a calculated mWS ≤4, only 64 (23.8%) had a D-dimer assay performed, with 30 (11.1%) having a PTE on CTPA. Among 75 patients with an mWS >4, 23 (30.7%) had a PTE on CTPA (P < 0.001). Compared to other prediction rules, an mWS>4 had the highest positive predictive value (31.0%) for PTE; all rules demonstrated similar negative predictive values for low-risk scores (87-89%). After adjusting for an 11% false negative rate for PTE in patients with low-risk mWS, overuse of CTPA was reported in up to 190 (55.2%) patients.ConclusionMore than 50% of patients with suspected PTE may be subject to unwarranted use of CTPA in the absence of pre-test clinical prediction rules coupled with D-dimer assays.© 2017 Royal Australasian College of Physicians.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.