• J Ultrasound Med · Oct 2018

    Intra- and Inter-rater Reliability of Navigated Ultrasound in the Assessment of Pelvic Tilt in Symptom-Free Young Adults.

    • Carlos J Marques, Tobias Martin, Franziska Fiedler, Mathias Weber, Viktor Breul, Frank Lampe, and Josef Kozak.
    • Research Center of the Orthopedic and Joint Replacement Department, Schoen Klinik Hamburg Eilbek, Hamburg, Germany.
    • J Ultrasound Med. 2018 Oct 1; 37 (10): 2333-2342.

    ObjectivesPelvic tilt is the angle between the anterior pelvic plane and the coronal plane. It affects cup positioning in total hip arthroplasty. The primary objective of this study was to test the intra- and inter-rater reliability of a navigated smart device-based ultrasound system for pelvic tilt assessment. The secondary objective was to test the inter-rater variability of the measurements on a hip phantom.MethodsA repeated-measures design was used. Two raters measured the pelvic tilt of 12 symptom-free young adults in upright and supine positions. Additionally, pelvic tilt was measured on a hip phantom. Each rater performed 3 measurements in each body position on the participants and 12 measurements on the hip phantom. Intra- and inter-rater reliability were calculated with the use of intraclass correlation coefficients. The variability in measurements on the hip phantom was assessed by a Bland-Altman analysis of agreement.ResultsIntraclass correlation coefficient 95% confidence intervals for intra-rater reliability ranged from good to excellent and moderate to excellent for the supine and upright positions respectively. Intraclass correlation coefficient 95% confidence intervals for inter-rater reliability ranged from poor to excellent for both positions. Hip phantom measurements showed no significant average bias (P > .05) and no significant proportional bias (P > .05). The 95% inter-rater limits of agreement were ±1.3° and ±1.7° for the supine and upright positions, respectively.ConclusionsThe intra-rater reliability values achieved were suitable. Intraclass correlation coefficient values for inter-rater reliability remained below an acceptable level. Possible reasons and overcoming strategies were presented. The 95% limits of agreement were good, at less than ±2°.© 2018 by the American Institute of Ultrasound in Medicine.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…