• Am. J. Ophthalmol. · Oct 2020

    Comparative Study

    Efficacy of Slit Lamp Breath Shields.

    • John Liu, Annie Y Wang, and Edsel B Ing.
    • Department of Ophthalmology and Visual Sciences, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia, Canada; Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario, Canada. Electronic address: liu.john520@gmail.com.
    • Am. J. Ophthalmol. 2020 Oct 1; 218: 120-127.

    PurposeTo evaluate the efficacy of slit lamp breath shields to prevent droplet spray from a simulated sneeze.DesignExperimental study to test the effectiveness of personal protective equipment.MethodsThe nozzle of a spray gun was adjusted to angularly disperse a mist of colored dye that approximated a patient sneezing on a dimensionally accurate cardboard slit lamp model. The designs of 6 commercially available breath shields and 1 breath shield repurposed from a plastic container lid were tested. Each breath shield was sprayed in a standardized fashion 3 times, and the amount of overspray was compared to spray with no shield and quantified. The surface area that was sprayed was calculated using a commercially available software with color range function. The average percentage of overspray of each breath shield was computed in comparison to the control.ResultsThe breath shields ranged in surface area from 116 to 924 cm2, and the amount of overspray varied from 54% to virtually none. Larger breath shields offered better protection than smaller ones. Breath shields attached to the objective lens arm were better barriers than those of comparable size hung by the oculars. A repurposed plastic lid breath shield, 513 cm2, was slightly curved toward the examiner's face and allowed only 2% overspray. The largest breath shield (924 cm2) hung near the oculars and prevented essentially all overspray.ConclusionsThe performance of different designs of breath shields was variable. Even high-functioning shields should be used in conjunction with personal protective equipment including masks, goggles, and gloves and handwashing. Ideally patients should also wear a face mask during all slit lamp examinations.Crown Copyright © 2020 Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.