- Xiaorong Wang, Daren Sawkey, and Qiuwen Wu.
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, 27710, USA.
- Med Phys. 2020 Jan 1; 47 (1): 164-170.
PurposeDynamic electron arc radiotherapy (DEAR) is a novel dynamic technique that achieves highly conformal dose through simultaneous couch and gantry motion during delivery. The purpose of this study is to develop a framework integrating a Monte Carlo dose engine (VirtuaLinac) to a treatment planning system (TPS, Eclipse) for DEAR. A quality assurance (QA) procedure is also developed.Methods And MaterialsThe interfaces include the following: computed tomography image export and conversion for VirtuaLinac; VirtuaLinac computation tasks management through application programming interface (API); and dose matrix processing and evaluation. The framework was validated with both static beam and DEAR plan with a 3 × 3 cm2 cutout for both 6 and 9 MeV electrons. Verification plans for DEAR were created on flat phantom and a hybrid dose calculation technique was developed which convolves precalculated small field kernel with the beam trajectory, and the resulting dose was compared with the full VirtuaLinac calculation and film measurement.ResultsExcellent agreement between VirtuaLinac and eMC was observed with three-dimensional γ pass rate of 98% at 1%/1 mm criteria for both 6 and 9 MeV electrons. Film measurement shows two-dimensional (2D) γ passing rate of 99.8 % (6 MeV) and 97.1% (9 MeV) at 2%/2 mm criteria. For DEAR plans the comparison of VirtuaLinac and measurement shows the 2D γ passing rates of 94% at 2%/2 mm for 6 MeV. The dose distributions from hybrid method in phantom are identical to the full VirtuaLinac simulations, but can be done instantly.ConclusionsA framework has been developed for DEAR dose calculation using VirtuaLinac Monte Carlo dose engine. The VirtuaLinac calculated dose was validated against measurement. A feasible and practical DEAR QA method has been developed for dose measurement in phantom. The hybrid dose calculation technique is efficient and suitable for DEAR QA purpose.© 2019 American Association of Physicists in Medicine.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*,_underline_or**bold**. - Superscript can be denoted by
<sup>text</sup>and subscript<sub>text</sub>. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3., hyphens-or asterisks*. - Links can be included with:
[my link to pubmed](http://pubmed.com) - Images can be included with:
 - For footnotes use
[^1](This is a footnote.)inline. - Or use an inline reference
[^1]to refer to a longer footnote elseweher in the document[^1]: This is a long footnote..