• Chest · Apr 1988

    Effects of expiratory flow resistance on inspiratory work of breathing.

    • M J Banner, J B Downs, R R Kirby, R A Smith, P G Boysen, and S Lampotang.
    • Department of Anesthesiology, College of Medicine, University of Florida, Gainesville 32610-0254.
    • Chest. 1988 Apr 1; 93 (4): 795-9.

    AbstractTo minimize work of breathing, airway pressure should not fluctuate during spontaneous breathing with continuous positive airway pressure (CPAP). However, flow resistance in the inspiratory limb of the breathing circuit and an inadequate continuous gas flow rate result in airway pressure fluctuation and increased work of breathing. Flow resistance of the expiratory pressure/exhalation valve also directly affects the level of airway pressure during spontaneous inhalation with CPAP (the greater the resistance of the valve, the greater the decrease in airway pressure and work of breathing). We compared this effect with three types of expiratory pressure valves: a threshold resistor with low resistance to flow, an inflatable balloon (mushroom) valve with moderate resistance to flow, and a variable-orifice flow resistor with a high resistance to flow. Work increased up to threefold with the balloon valve and more than tenfold with the flow resistor compared with the threshold resistor. To apply CPAP, expiratory pressure valves with low resistance to flow should be used to minimize fluctuations in airway pressure and, thus, in the work of spontaneous breathing.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.