• World Neurosurg · Jul 2021

    The Geometry of Y-stent Configurations Used for Wide-Necked Aneurysm Treatment: Analyzing Double-Barrel Stents in vitro Using Flat-Panel CT.

    • M Travis Caton, Alexander Z Copelan, Kazim H Narsinh, Amanda Baker, Adib A Abla, Randall T Higashida, Matthew R Amans, Steven W Hetts, and Daniel L Cooke.
    • Department of Neurointerventional Radiology, University of California San Francisco, San Francisco, California, USA. Electronic address: Michael.caton2@ucsf.edu.
    • World Neurosurg. 2021 Jul 1; 151: e363-e371.

    BackgroundStent-assisted coil embolization of wide-necked bifurcation aneurysms often employs a Y configuration stent. A similar stent configuration, termed kissing/double-barrel (KDB), is used often at the aortoiliac bifurcation. Studies of KDB stents in aortoiliac disease show that rates of thromboembolic complications vary with the cross-sectional geometry of the stent pair, a function of the radial crush resistive force of each stent. We assessed cross-sectional geometry of intracranial stent pairs in an in vitro model of the basilar artery using flat-panel computed tomography.MethodsIn a silicone model of a wide-necked basilar tip aneurysm, 6 simulated KDB stent deployment trials were performed using combinations of 5 stents (Enterprise 1, Enterprise 2, Neuroform Atlas, LVIS, LVIS Jr.). Flat-panel computed tomography reconstructions were used to assess cross-sectional stent geometry. Relative conformability, defined by ovalization and D-ratio, radial crush resistive force (predicted vs. actual), and radial mismatch fraction were compared by stent type (braided vs. laser-cut).ResultsSeveral distinct forms of cross-sectional stent geometry were observed. Braided stents had lower ovalization and D-ratio (P = 0.015) than laser-cut stents. The Neuroform Atlas/LVIS combination yielded the lowest radial mismatch fraction (19.7% vs. mean 44.3% ± 0.7%). Braided stents tended to have a deployed stent radius closer to the expected (nominal) diameter (i.e., higher relative crush resistive force) than laser-cut stents (measured vs. nominal diameter discrepancy +38.6% ± 21.1% vs. -10.7% ±16.1%, P = 0.14).ConclusionsIn constant anatomy, cross-sectional geometry of the KDB stent configuration will vary depending on the design and structure of the stents employed.Copyright © 2021 The Author(s). Published by Elsevier Inc. All rights reserved.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…