• J. Heart Lung Transplant. · Aug 2016

    Novel echocardiographic parameters of aortic insufficiency in continuous-flow left ventricular assist devices and clinical outcome.

    • Jonathan Grinstein, Eric Kruse, Gabriel Sayer, Savitri Fedson, Gene H Kim, Nitasha Sarswat, Sirtaz Adatya, Takeyoshi Ota, Valluvan Jeevanandam, Victor Mor-Avi, Roberto M Lang, and Nir Uriel.
    • Department of Medicine, University of Chicago Medical Center, Chicago, Illinois, USA.
    • J. Heart Lung Transplant. 2016 Aug 1; 35 (8): 976-85.

    BackgroundThe aim of this study was to evaluate the prognostic performance of novel echocardiographic (transthoracic echocardiography, or TTE) parameters for grading aortic insufficiency (AI) severity in patients with continuous-flow left ventricular assist devices (CF-LVADs). The development of AI after CF-LVAD implantation is common, although the clinical significance remains unclear. We previously described novel TTE parameters that outperformed traditional TTE parameters in grading AI severity in these patients.MethodsCF-LVAD patients with varying degrees of AI (N = 57) underwent Doppler TTE of the LVAD outflow cannula. Patients had AI severity graded by the novel parameters (systolic/diastolic velocity ratio and the diastolic acceleration of the LVAD outflow cannula) and the traditional vena contracta. The prognostic performance of novel and traditional AI parameters was determined by comparing rates of congestive heart failure re-admission, need for aortic valve intervention, urgent transplantation and death (composite end-points) for each parameter.ResultsGrading AI severity using novel AI parameters led to reclassification of 32% of patients from trace/mild AI to moderate or greater AI (N = 18). Using traditional AI parameters, there was no difference in the occurrence of the composite end-point between the moderate or greater group and the trace/mild group (1.50 vs 1.18 events/person, p = 0.46). With the novel AI parameters, there were significantly more events in the patients with moderate or greater AI compared to those with trace/mild AI (1.57 vs 0.13 events/person, p = 0.002). Novel parameters also better predicted the need for aortic valve intervention, urgent transplantation or death than traditional methods (p = 0.024 vs p = 0.343).ConclusionsIn patients with CF-LVADs, traditional parameters tend to underestimate AI severity and future cardiac events. Novel AI TTE parameters are better able to discriminate AI severity and predict clinically meaningful outcomes.Copyright © 2016 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…