• Spine · Nov 2012

    Biomechanical analysis of corrective forces in spinal instrumentation for scoliosis treatment.

    • Xiaoyu Wang, Carl-Eric Aubin, Hubert Labelle, Stefan Parent, and Dennis Crandall.
    • Department of Mechanical Engineering, Ecole Polytechnique de Montréal, Montreal, QC, Canada.
    • Spine. 2012 Nov 15;37(24):E1479-87.

    Study DesignComputer modeling and simulations to analyze correction forces at the bone-screw interface in scoliosis instrumentation.ObjectiveTo derive the minimum corrective forces applied on vertebrae through pedicle screws to achieve desired scoliosis corrections and evaluate the actual bone-screw forces associated with 3 types of pedicle screws (monoaxial, polyaxial, and dorsoaxial).Summary Of Background DataThe optimum screw pattern has not been established in the literature. The final bone-screw forces in scoliosis instrumentation consist of "true corrective forces" (i.e., the minimum forces required to achieve the desired corrections without considering adequate rod seating at all pedicle screws) and "extra forces" (EF) (i.e., supplementary forces applied to ensure proper rod seating when the attachment of some screws is not in compliance with the attachment of their neighboring screws; they have no benefit to overall corrections). METHODS.: Using patient-specific computer models, true corrective forces were estimated for 10 spinal instrumentation cases. EF were computed by simulating the instrumentations of the 10 cases using respectively monoaxial, polyaxial, and dorsoaxial screws.ResultsThe average true corrective forces were 50 ± 30 N. The average bone-screw forces were 229 ± 140 N, 141 ± 99 N, and 103 ± 42 N, respectively, for monoaxial, polyaxial, and dorsoaxial screws; the averages of the EF magnitudes were 205 ± 136 N, 125 ± 93 N, and 65 ± 39 N, respectively.ConclusionBone-screw forces to achieve desired corrections can be minimized. However, EF are inevitable to secure the locking of all screws. Higher EF were associated with pedicle screws, with less degrees of freedom for connecting screw body to rod, that is, monoaxial followed by polyaxial and then by dorsoaxial screws.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…