• Spine · Dec 2012

    Multicenter Study

    A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and StealthStation Navigation.

    • Erik Van de Kelft, F Costa, D Van der Planken, and F Schils.
    • Department of Neurosurgery, AZ Nikolaas, Sint Niklaas, Belgium. erik.vandekelft@neuro-chirurgie.org
    • Spine. 2012 Dec 1;37(25):E1580-7.

    Study DesignAn international, multicenter, prospective, postmarketing clinical registry to record the accuracy of pedicle screw placement, using the O-arm Complete Multidimensional Surgical Imaging System with StealthStation Navigation.ObjectiveTo evaluate the accuracy of pedicle screw placement in common neurosurgical practice and assess the patient's radiation exposure.Summary Of Background DataSeveral imaging techniques have been used to increase accurate pedicle screw placement. The O-arm 3-dimensional (3D) imaging (Medtronic Navigation, Louisville, CO), an intraoperative computed tomographic (CT) scan, combined with an existing navigation system was reported to further increase accuracy of screw placement, especially because an intraoperative 3D scan provides information for screw adjustment before wound closure.MethodsPatients already planned for instrumented spinal surgery were operated while using the O-arm as imaging device and the StealthStation Navigation (Medtronic Navigation, Louisville, CO) as navigation tool. At the end of all pedicle screw insertions, the placement was classified according to a validated method. The accuracy of pedicle screw placement based on the intraoperative 3D scan and the surgeon's perception of correct screw placement were assessed as well as the radiation doses the patient received during the entire procedure.ResultsDuring a 16-month period, a total of 1922 screws in 353 patients were evaluated. In 97.5%, the screws were correctly placed. Only 2.5% of the screws were considered as misplaced, and 1.8% of the screws were revised during the same procedure. When the surgeon perceived the screws to be correctly placed, the CT scan verified his assessment in 98.5% of the cases. The mean radiation dose was comparable with half the dose of a 64 multislice CT scan.ConclusionThe use of the O-arm in combination with a navigation system increases the accuracy of pedicle screw placement. The accuracy of the surgeon's perception and the need to limit the radiation dose for the patient justify an additional CT scan only after careful assessment of the potential additional value.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…