-
- Andreas Becker, Daniela Kuhnt, Udo Bakowsky, and Christopher Nimsky.
- Department of Neurosurgery, University of Marburg, Baldingerstrasse, Marburg, Germany. andreas.becker@staff.uni-marburg.de
- Neurosurgery. 2012 Dec 1;71(2 Suppl Operative):ons296-301; discussion ons301.
BackgroundDuring external ventricular drainage (EVD) weaning, cranial computed tomography (cCT) is necessary to evaluate ventricle width. Because intrahospital transfer of critically ill patients is associated with higher mortality, bedside techniques are necessary to evaluate ventricle width. Transcranial sonography is able to show the ventricles in patients with sufficient temporal acoustic window. Contrast-enhanced ultrasound (CEUS) is able to overcome the limitations of insufficient insonation.ObjectiveWe demonstrate the feasibility of bedside transcranial CEUS ventriculography to measure ventricles and verify the passage of cerebrospinal fluid (CSF) through the foramen of Magendie into the subarachnoid space during EVD weaning in critically ill patients.MethodsSix patients were examined by transcranial and transnuchal CEUS. Harmonic imaging with low mechanical index was used. One milliliter of an ultrasound contrast agent was administered via EVD line. Comparison with the cCT scans at the time of discharge was used to confirm CEUS-ventriculography results.ResultsVentricles were visualized in all patients. CSF transmission via the foramen of Magendie was demonstrated in 5 patients. Mean ventricle width (centimeters) was 0.67 (CEUS) vs 0.73 (cCT) (standard deviation 0.43, 0.45, P = .116) [third ventricle], 0.88 vs 1.02 (0.28, 0.22, P = .055) [fourth ventricle], 1.40 vs 1.37 (0.56, 0.54, P = .620) [left lateral ventricle], 1.37 vs 1.37 (0.55, 0.54, P = .952) [right lateral ventricle], 2.33 vs 2.23 (0.51, 0.58, P = .169) [left anterior horn], and 2.25 vs 2.07 (0.56, 0.64, P = .204) [right anterior horn]. Mean duration for CEUS ventriculography was 3:15 minutes.ConclusionCEUS ventriculography is an effective bedside procedure in critically ill patients with EVD. CEUS allows measurement of ventricle width, ventricle communication, and CSF transfer to the subarachnoidal space through the cisternal foramina.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.