-
Journal of neurosurgery · Nov 2021
Suction mask device: a simple, inexpensive, and effective method of reducing spread of aerosolized particles during endoscopic endonasal surgery in the era of COVID-19.
- Takuma Hara, Marcus A Zachariah, Ruichun Li, Rafael Martinez-Perez, Ricardo L Carrau, and Daniel M Prevedello.
- Departments of1Neurosurgery and.
- J. Neurosurg. 2021 Nov 1; 135 (5): 132813341328-1334.
ObjectiveAerosol-generating procedures, including endoscopic endonasal surgery (EES), are a major risk for physicians during the COVID-19 pandemic. Techniques for reducing aerosolization and risk of transmission of COVID-19 during these procedures would be valuable to the neurosurgical community. The authors aimed to simulate the generation of small-particle aerosols during EES and craniectomy in order to develop methods to reduce the spread of aerosolized particles, and to test the effectiveness of these methods.MethodsThis study was performed at the Anatomical Laboratory for Visuospatial Innovations in Otolaryngology and Neurosurgery at The Ohio State University. The following two scenarios were used to measure three different particle sizes (0.3, 2.5, and 10 µm) generated: 1) drilling frontotemporal bone, simulating a craniectomy; and 2) drilling sphenoid bone, simulating an endonasal approach. A suction mask device was created with the aim of reducing particle release. The presence of particles was measured without suction, with a single Frazier tip suction in the field, and with the suction mask device in addition to the Frazier suction tip. Particles were measured 12 cm from the craniectomy or endonasal drilling region.ResultsIn the absence of any aerosol-reducing devices, the number of particles measured during craniectomy was significantly higher than that generated by endonasal drilling. This was true regardless of the particle size measured (0.3 µm, p < 0.001; 2.5 µm, p < 0.001; and 10 µm, p < 0.001). The suction mask device reduced the release of particles of all sizes measured in the craniectomy simulation (0.3 µm, p < 0.001; 2.5 µm, p < 0.001; and 10 µm, p < 0.001) and particles of 0.3 µm and 2.5 µm in the single Frazier suction simulation (0.3 µm, p = 0.031; and 2.5 µm, p = 0.026). The suction mask device further reduced the release of particles of all sizes during EES simulation (0.3 µm, p < 0.001; and 2.5 µm, p < 0.001) and particles of 0.3 µm and 2.5 µm in the single Frazier suction simulation (0.3 µm, p = 0.033; and 2.5 µm, p = 0.048). Large particles (10 µm) were not detected during EES.ConclusionsThe suction mask device is a simple and effective means of reducing aerosol release during EES, and it could potentially be used during mastoidectomies. This could be a valuable tool to reduce the risk of procedure-associated viral transmission during the COVID-19 pandemic.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.