• Cochrane Db Syst Rev · Mar 2019

    Meta Analysis

    Cyclodestructive procedures for refractory glaucoma.

    • Monica F Chen, Carole H Kim, and Anne L Coleman.
    • Stein Eye Institute, UCLA, 100 Stein Plaza, Los Angeles, California, USA, 90095.
    • Cochrane Db Syst Rev. 2019 Mar 10; 3: CD012223.

    BackgroundCyclodestructive procedures are often used in patients with refractory glaucoma who have failed to achieve lower intraocular pressure (IOP) from filtration procedures and maximal medical therapy. Destruction of the ciliary body helps to lower IOP by reducing aqueous humor formation. Of the many types of cyclodestructive procedures, laser cyclophotocoagulation (CPC) has become the most common surgical method for reducing aqueous inflow. Options for CPC are wide-ranging: they can be performed using a neodymium:yttrium-aluminum-garnet (Nd:YAG) or diode laser and laser energy can be delivered by either the contact or non-contact method. Another cyclodestructive procedure is endoscopic cyclophotocoagulation (ECP), which the ophthalmologist can use selectively to target the ciliary epithelium and ablate ciliary body tissue. There is debate regarding which cyclodestructive method is best and how they compare to other glaucoma surgeries.ObjectivesTo assess the relative effectiveness and safety of cyclodestructive procedures compared with other procedures in people with refractory glaucoma of any type and to assess the relative effectiveness and safety of individual cyclodestructive procedures compared with each other.Search MethodsWe searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2018, Issue 9); Ovid MEDLINE; Embase.com; PubMed; LILACS BIREME; ClinicalTrials.gov and the WHO ICTRP. The date of the search was 21 September 2018.Selection CriteriaWe included randomized controlled trials or quasi-randomized trials in which participants underwent a secondary procedure for refractory glaucoma. We included trials with any laser type, route of administration, and laser settings. The primary comparison was any cyclodestructive procedure versus another glaucoma treatment, and the secondary comparisons were individual cyclodestructive procedures versus another cyclodestructive procedure.Data Collection And AnalysisTwo review authors independently reviewed the titles and abstracts from the database searches, and after retrieving the full-text reports of those that were potentially relevant, classified the full-text articles as included or excluded. Two review authors independently extracted data from the included studies and assessed the risk of bias. Discrepancies were resolved by discussion or by consultation with a third review author when necessary.Main ResultsWe included five trials reporting data for 330 eyes (326 participants). One study to had a low risk of bias for most domains and the other studies had an overall unclear risk of bias. This review includes four different comparisons: 1) ECP versus Ahmed implant, 2) micropulse CPC versus continuous-wave CPC; 3) CPC with a diode versus Nd:YAG laser; and 4) CPC with an Nd:YAG laser emitting 8J versus 4J.No study reported data for our primary outcome, change from baseline in pain severity as reported by the participant or change in number of pain medications.For our primary comparison, we included one trial that compared ECP with the Ahmed implant. At 12-month follow-up, the mean difference (MD) in IOPs between groups was -1.14 mmHg (95% confidence interval (CI) -4.21 to 1.93; 58 participants; low-certainty evidence (LCE)). At 24 months postintervention, we found very LCE suggesting that visual acuity may be better among participants in the ECP group than in the Ahmed implant group (MD -0.24 logMAR, 95% CI -0.52 to 0.04; 54 participants), and the difference in the mean number of glaucoma medications used by participants in each group was unclear (MD -0.50, 95% CI -1.17 to 0.17; 54 participants; very LCE). Reported adverse events in the ECP group (34 participants) were one case each of hypotony, phthisis bulbi, retinal detachment, and choroidal detachment; in the Ahmed implant group (34 participants) there was one case of endophthalmitis, two cases of retinal detachment, and six cases of choroidal detachment.Three types of comparisons from four included studies provided data for our secondary comparisons. In the study that compared micropulse with continuous-wave CPC, median IOP was reported to be similar between the two groups at all time points. At 18 months postintervention, the median number of IOP-lowering medications was reduced from two to one in both groups. One participant in the micropulse and two in the continuous group exhibited worsened visual acuity. One case of prolonged inflammation was seen in the micropulse group (23 participants). Seven cases of prolonged inflammation, five cases of hypotony, and one case of phthisis bulbi were seen in the continuous group (23 participants).Two studies compared CPC using a semiconductor diode versus an Nd:YAG laser. At 12 months postintervention, the MD in IOP was 1.02 mmHg (95% CI -1.49 to 3.53) in one study (LCE). The second study did not report mean IOP beyond three months of follow-up. Neither study reported the mean change in best-corrected visual acuity or number of glaucoma medications. Both studies reported hypotony as an adverse event in three participants in each study.One study compared different energy settings of the same Nd:YAG laser. At 12-month follow-up, visual acuity was unchanged or improved in 21 of 33 participants in the 8J group and 20 of 27 participants in the 4J group (risk ratio 0.86, 95% CI 0.61 to 1.21; very LCE). More participants in the 8J group reduced the number of medications taken compared with the 4J group (RR 1.49, 95% CI 0.76 to 2.91; 50 participants; very low-certainty evidence). The presence of fibrin or hyphema were seen in five participants who received 8J and none who received 4J. There was a severe anterior chamber reaction in 11 of 26 (42%) participants who received 8J of energy and 2 of 21 (10%) participants who received 4J of energy.Authors' ConclusionsEvidence from five studies included in this review was inconclusive as to whether cyclodestructive procedures for refractory glaucoma result in better outcomes and fewer complications than other glaucoma treatments, and whether one type of cyclodestructive procedure is better than another. The most commonly reported adverse events across all five studies were hypotony and phthisis bulbi. Large, well-designed randomized controlled trials are needed. Patient-reported outcomes such as pain and quality of life should be considered as primary outcomes or important secondary outcomes of future trials.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.