• J Chiropr Med · Sep 2018

    Reliability of Electromyographic Assessment of Biceps Brachii and Triceps Brachii in Cricketers.

    • Deepika Singla, Mohammad Ejaz Hussain, Pooja Bhati, Jamal Ali Moiz, Irshad Ahmad, Shalini Verma, and Kamran Ali.
    • Centre for Physiotherapy and Rehabilitation Sciences, Jamia Millia Islamia, Jamia Nagar, Okhla, Delhi, India.
    • J Chiropr Med. 2018 Sep 1; 17 (3): 151-159.

    ObjectiveThe purpose of this study is to determine the intraexaminer and interexaminer reliability of electromyographic assessment of biceps brachii (BB) and triceps brachii (TB) muscles in cricketers.MethodsSixteen healthy male cricketers (ages 14-35 years) recruited from Jamia Millia Islamia, New Delhi, India were tested on 2 occasions that were held 1 week apart. On the first occasion, only examiner 1 performed the testing; on the second occasion, examiner 1, examiner 2, and examiner 3 all performed testing. While testing for surface electromyography (sEMG) activity of BB and TB muscles, participants were asked to produce maximal voluntary isometric contraction (MVIC), which was to be held for 5 seconds against the resistance provided by an examiner. Participants performed 3 MVICs per muscle per examiner, with a rest interval of 3 minutes between consecutive contractions. Intraclass correlation coefficient, standard error of measurement, and minimum detectable change were calculated to determine the reliability of repeated sEMG measurements.ResultsNonsignificant differences were observed for the 2 trials completed by examiner 1 (paired t test) and testing done by all 3 examiners (repeated measures analysis of variance) at P < .05 for both BB and TB. Intraclass correlation coefficient values ranged from .84 to .86 for BB and .89 to .98 for TB. Standard error of measurement (minimum detectable change) was .052 (.144) mV and .041 (.114) mV for BB intraexaminer and interexaminer reliability testing, respectively, and .018 (.051) mV and .043 (.119) mV for TB intraexaminer and interexaminer reliability testing. Ninety-five percent of the mean differences between almost all of the repeated measurements were found to lie within the agreement intervals estimated by Bland-Altman plots.ConclusionThis preliminary study suggests that sEMG is a reliable tool with excellent intraexaminer and interexaminer reliability for assessing the activity of BB and TB muscles in male cricketers. These findings suggest that sEMG can be used to assess MVIC activity of these muscles in clinical settings, as well as in research area.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…