• Invest. Ophthalmol. Vis. Sci. · Sep 2011

    Comparative Study

    Comparison of standard automated perimetry, frequency-doubling technology perimetry, and short-wavelength automated perimetry for detection of glaucoma.

    • Shu Liu, Shi Lam, Robert N Weinreb, Cong Ye, Carol Y Cheung, Gilda Lai, Dennis Shun-Chiu Lam, and Christopher Kai-Shun Leung.
    • Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong, Peoples Republic of China.
    • Invest. Ophthalmol. Vis. Sci. 2011 Sep 21; 52 (10): 7325-31.

    PurposeTo compare the performance of standard automated perimetry (SAP), frequency-doubling technology (FDT) perimetry, and short-wavelength automated perimetry (SWAP) in detecting glaucoma.MethodsOne hundred thirty-two eyes of 95 glaucoma patients and 37 normal subjects had retinal nerve fiber layer (RNFL) imaging and visual field testing by SAP, Matrix FDT perimetry, and Swedish interactive thresholding algorithm (SITA) SWAP at the same visit (all perimeters by Carl Zeiss Meditec, Inc., Dublin, CA). Visual field defects were confirmed with two or more consecutive examinations by the same types of perimetry. Glaucoma was defined with the reference to the RNFL thickness deviation map score (≥ 4, glaucomatous; ≤ 2, normal). The sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) of MD (mean deviation) and PSD (pattern standard deviation) of the perimetries were compared.ResultsTaking all glaucoma patients into consideration, the sensitivity was highest for Matrix FDT perimetry (69%), followed by SAP (68%), and then SITA SWAP (59%). When the analysis included only patients with early glaucoma, the sensitivity decreased to 52%, 46%, and 34%, respectively, with a significant difference detected between Matrix FDT perimetry and SITA SWAP (P = 0.034). The specificity was ≥ 97% for all perimetries. The AUCs of MD and PSD followed a similar order, with Matrix FDT perimetry having the greatest AUC (0.89-0.94), followed by SAP (0.87-0.94), and then SITA SWAP (0.69-0.90). There were significant differences in sensitivities at 90% specificity between Matrix FDT perimetry and SITA SWAP (P ≤ 0.005 for MD; P ≤ 0.039 for PSD).ConclusionsThe performance for glaucoma detection was comparable between FDT perimetry and SAP. FDT perimetry had a higher sensitivity for detecting glaucoma than did SWAP at a comparable level of specificity.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…