• Br J Obstet Gynaecol · Aug 1997

    Effect of location of the sensor on reflectance pulse oximetry.

    • A C Dassel, R Graaff, M Aardema, W G Zijlstra, and J G Aarnoudse.
    • Department of Obstetrics and Gynaecology, University Hospital Groningen, The Netherlands.
    • Br J Obstet Gynaecol. 1997 Aug 1; 104 (8): 910-6.

    ObjectiveThe influence of the location of the sensor on reflectance pulse oximetry during fetal monitoring in labour was investigated using the newborn infant as a model.MethodsSeven healthy infants were studied between 19 and 48 hours after term delivery. Recordings of reflectance pulse oximetry were obtained from eight different sites on the infant's head. The relative changes in red to infrared light (R/IR) were determined. In pulse oximetry R/IR values are converted to arterial oxygen values by means of an empirically derived calibration curve.ResultsSignificantly lower R/IR values were found at the forehead compared with the fontanelle, the parietal and occipital position, and the temporal area. Conversion to oxygen saturation values revealed a difference of up to 13.4% in oxygen saturation between the forehead and the occipital area.ConclusionAssuming that the arterial blood oxygen saturation did not change substantially, our findings indicate that in reflectance pulse oximetry there is no unique relation between R/IR and arterial oxygen saturation. The differences in reflectance pulse oximetry at the various sites are explained by differences in optical properties (scattering and absorption) of the tissue underneath the sensor. These will affect the red and infrared light reaching the detectors in a different way, and consequently R/IR changes. Because during intrapartum monitoring exact positioning of the sensor on the fetal head is usually impossible, the accuracy of fetal reflectance pulse oximetry is impaired.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.