• Spine · Sep 2012

    The biomechanical effect of pedicle screws' insertion angle and position on the superior adjacent segment in 1 segment lumbar fusion.

    • Ho-Joong Kim, Heoung-Jae Chun, Kyoung-Tak Kang, Seong-Hwan Moon, Hak-Sun Kim, Jin-Oh Park, Eun-Su Moon, Bo-Ram Kim, Joon-Seok Sohn, Yu-Na Ko, and Hwan-Mo Lee.
    • Spine Center and Department of Orthopaedic Surgery, Seoul National University College of Medicine and Seoul National University Bundang Hospital, Seoul, Korea.
    • Spine. 2012 Sep 1;37(19):1637-44.

    Study DesignA finite element analysis.ObjectiveTo investigate the association between the position of an inserted pedicle screw and the corresponding facet contact force or intradiscal pressure.Summary Of Background DataAlthough superior facet joint violation by pedicle screws is not an uncommon occurrence in instrumented lumbar fusion surgery, its actual biomechanical significance is not well understood. Furthermore, the association between the position of the pedicle screw and the stress on the corresponding disc/facet joint has yet to be investigated.MethodsAccording to the positions of pedicle screws in L4 of the L4-L5 lumbar fusion, 4 L4-L5 fusion models were simulated. These models included the violation of both L3-L4 superior facet joints by pedicle screws (facet joint violation [FV] model), the nonencroachment of both L3-L4 superior facet joints by pedicle screws (facet joint preservation [FP] model), and the removal state of pedicle screws in the FV model (removal of violated pedicle screws [rFV] model). The facet joint contact [FC] model represented the scenario in which the pedicle screws did not encroach upon either facet joint but were inserted close to the L3-L4 facet joint surface. Moreover, the uninstrumented fusion [UF] model represented the uninstrumented L4-L5 fusion. In each scenario, the intradiscal pressures and facet contact forces at the L2-L3 and L3-L4 segments were analyzed under extension and torsion moments.ResultsThe FV model yielded the greatest increases in facet contact force and intradiscal pressure at the L3-L4 segment under extension and torsion moments. Following the FV model, the increases in intradiscal pressure and facet contact force were the second highest in the FC model followed by the FP model. Furthermore, the rFV model represented prominent reductions of previously increased facet contact force and intradiscal pressure at the L3-L4 segment.ConclusionIn models of 1-segment lumbar fusion surgery, the positions of pedicle screws were closely linked with corresponding disc stresses and facet contact forces. However, even in cases of facet violation by pedicle screws, removal of the pedicle screw after fusion completion can reduce facet contract forces and disc stresses under both extension and torsional moments.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…