-
Circ Cardiovasc Interv · Apr 2017
Multicenter Study Comparative StudyMatched Comparison of Self-Expanding Transcatheter Heart Valves for the Treatment of Failed Aortic Surgical Bioprosthesis: Insights From the Valve-in-Valve International Data Registry (VIVID).
- Sami Alnasser, Asim N Cheema, Matheus Simonato, Marco Barbanti, Jeremy Edwards, Ran Kornowski, Eric Horlick, Harindra C Wijeysundera, Luca Testa, Francesco Bedogni, Hafid Amrane, Thomas Walther, Marc Pelletier, Azeem Latib, Jean-Claude Laborde, David Hildick-Smith, Won-Keun Kim, Didier Tchetche, Marco Agrifoglio, Jan-Malte Sinning, Ad J van Boven, Joëlle Kefer, Christian Frerker, Nicolas M van Mieghem, Axel Linke, Stephen Worthley, Anita Asgar, Carmelo Sgroi, Mina Aziz, Haim D Danenberg, Marino Labinaz, Ganesh Manoharan, Anson Cheung, John G Webb, Danny Dvir, and Valve-in-Valve International Data Registry Investigators.
- From the St. Michael's Hospital, Toronto, Canada (S.A., A.N.C., J.E.); St. Paul's Hospital, Vancouver, Canada (M.S., M. Aziz, A.C., J.G.W., D.D.); Ferrarotto Hospital, University of Catania, Italy (M.B., C.S.); Rabin Medical Center, Tel Aviv, Israel (R.K.); Peter Munk Cardiac Center, Toronto, Canada (E.H.); Schulich Heart Centre, Division of Cardiology, Sunnybrook Health Sciences Centre, Toronto, Canada (H.C.W.); Department of Cardiology, IRCCS Pol. S. Donato, Milan, Italy (L.T., F.B.); Medisch Centrum Leeuwarden, Netherlands (H.A., A.J.v.B.); Kerckhoff-Klinik Bad Nauheim, Germany (T.W., W.-K.K.); New Brunswick Heart Center, Saint John, Canada (M.P.); San Raffaele Scientific Institute, Milan, Italy (A. Latib); St. George's Hospital, London, England (J.-C.L.); Sussex Cardiac Centre, Brighton, England (D.H.-S.); Clinique Pasteur, Toulouse, France (D.T.); Centro Cardiologico Monzino, Milan, Italy (M. Agrifoglio); Heart Center, University Hospital Bonn, Germany (J.-M.S.); University Clinics Saint Luc, Brussels, Belgium (J.K.); Asklepios Klinik St. Georg Hospital, Hamburg, Germany (C.F.); Erasmus University Medical Center, Rotterdam, Netherlands (N.M.v.M.); Heart Center, University of Leipzig, Germany (A. Linke); Royal Adelaide Hospital, Australia (S.W.); Montreal Heart Institute, Canada (A.A.); Hadassah Hebrew University Medical Center, Jerusalem, Israel (H.D.D.); Ottawa Heart Institute, Canada (M.L.); and Royal Victoria Hospital, Belfast, United Kingdom (G.M.).
- Circ Cardiovasc Interv. 2017 Apr 1; 10 (4).
BackgroundTranscatheter valve-in-valve implantation is an established therapy for high-risk patients with failed surgical aortic bioprosthesis. There are limited data comparing outcomes of valve-in-valve implantation using different transcatheter heart valves (THV).Methods And ResultsPatients included in the Valve-in-Valve International Data registry (VIVID) and treated with self-expanding THV devices were analyzed using centralized core laboratory blinded to clinical events. St. Jude Medical Portico versus Medtronic CoreValve were compared in a 1:2 fashion after propensity score matching. A total of 162 patients, Portico- (n=54) and CoreValve- (n=108) based valve-in-valve procedures comprised the study population with no significant difference in baseline characteristics (age, 79±8.2 years; 60% women; mean STS [Society of Thoracic Surgery] score 8.1±5.5%). Postimplantation, CoreValve was associated with a larger effective orifice area (1.67 versus 1.31 cm2; P=0.001), lower mean gradient (14±7.5 versus 17±7.5 mm Hg; P=0.02), and lower core laboratory-adjudicated moderate-to-severe aortic insufficiency (4.2% versus 13.7%; P=0.04), compared with Portico. Procedural complications including THV malpositioning, second THV requirement, or coronary obstruction were not significantly different between the 2 groups. Survival and stroke rates at 30 days were similar, but overall mortality at 1 year was higher among patients treated with Portico compared with CoreValve (22.6% versus 9.1%; P=0.03).ConclusionsIn this first matched comparison of THVs for valve-in-valve implantations, Portico and CoreValve demonstrated differences in postprocedural hemodynamics and long-term clinical outcomes. Although this could be related to THV design characteristics, the impact of other procedural factors cannot be excluded and require further evaluation.© 2017 American Heart Association, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.