• Circ Cardiovasc Interv · Apr 2017

    Multicenter Study Comparative Study

    Matched Comparison of Self-Expanding Transcatheter Heart Valves for the Treatment of Failed Aortic Surgical Bioprosthesis: Insights From the Valve-in-Valve International Data Registry (VIVID).

    • Sami Alnasser, Asim N Cheema, Matheus Simonato, Marco Barbanti, Jeremy Edwards, Ran Kornowski, Eric Horlick, Harindra C Wijeysundera, Luca Testa, Francesco Bedogni, Hafid Amrane, Thomas Walther, Marc Pelletier, Azeem Latib, Jean-Claude Laborde, David Hildick-Smith, Won-Keun Kim, Didier Tchetche, Marco Agrifoglio, Jan-Malte Sinning, Ad J van Boven, Joëlle Kefer, Christian Frerker, Nicolas M van Mieghem, Axel Linke, Stephen Worthley, Anita Asgar, Carmelo Sgroi, Mina Aziz, Haim D Danenberg, Marino Labinaz, Ganesh Manoharan, Anson Cheung, John G Webb, Danny Dvir, and Valve-in-Valve International Data Registry Investigators.
    • From the St. Michael's Hospital, Toronto, Canada (S.A., A.N.C., J.E.); St. Paul's Hospital, Vancouver, Canada (M.S., M. Aziz, A.C., J.G.W., D.D.); Ferrarotto Hospital, University of Catania, Italy (M.B., C.S.); Rabin Medical Center, Tel Aviv, Israel (R.K.); Peter Munk Cardiac Center, Toronto, Canada (E.H.); Schulich Heart Centre, Division of Cardiology, Sunnybrook Health Sciences Centre, Toronto, Canada (H.C.W.); Department of Cardiology, IRCCS Pol. S. Donato, Milan, Italy (L.T., F.B.); Medisch Centrum Leeuwarden, Netherlands (H.A., A.J.v.B.); Kerckhoff-Klinik Bad Nauheim, Germany (T.W., W.-K.K.); New Brunswick Heart Center, Saint John, Canada (M.P.); San Raffaele Scientific Institute, Milan, Italy (A. Latib); St. George's Hospital, London, England (J.-C.L.); Sussex Cardiac Centre, Brighton, England (D.H.-S.); Clinique Pasteur, Toulouse, France (D.T.); Centro Cardiologico Monzino, Milan, Italy (M. Agrifoglio); Heart Center, University Hospital Bonn, Germany (J.-M.S.); University Clinics Saint Luc, Brussels, Belgium (J.K.); Asklepios Klinik St. Georg Hospital, Hamburg, Germany (C.F.); Erasmus University Medical Center, Rotterdam, Netherlands (N.M.v.M.); Heart Center, University of Leipzig, Germany (A. Linke); Royal Adelaide Hospital, Australia (S.W.); Montreal Heart Institute, Canada (A.A.); Hadassah Hebrew University Medical Center, Jerusalem, Israel (H.D.D.); Ottawa Heart Institute, Canada (M.L.); and Royal Victoria Hospital, Belfast, United Kingdom (G.M.).
    • Circ Cardiovasc Interv. 2017 Apr 1; 10 (4).

    BackgroundTranscatheter valve-in-valve implantation is an established therapy for high-risk patients with failed surgical aortic bioprosthesis. There are limited data comparing outcomes of valve-in-valve implantation using different transcatheter heart valves (THV).Methods And ResultsPatients included in the Valve-in-Valve International Data registry (VIVID) and treated with self-expanding THV devices were analyzed using centralized core laboratory blinded to clinical events. St. Jude Medical Portico versus Medtronic CoreValve were compared in a 1:2 fashion after propensity score matching. A total of 162 patients, Portico- (n=54) and CoreValve- (n=108) based valve-in-valve procedures comprised the study population with no significant difference in baseline characteristics (age, 79±8.2 years; 60% women; mean STS [Society of Thoracic Surgery] score 8.1±5.5%). Postimplantation, CoreValve was associated with a larger effective orifice area (1.67 versus 1.31 cm2; P=0.001), lower mean gradient (14±7.5 versus 17±7.5 mm Hg; P=0.02), and lower core laboratory-adjudicated moderate-to-severe aortic insufficiency (4.2% versus 13.7%; P=0.04), compared with Portico. Procedural complications including THV malpositioning, second THV requirement, or coronary obstruction were not significantly different between the 2 groups. Survival and stroke rates at 30 days were similar, but overall mortality at 1 year was higher among patients treated with Portico compared with CoreValve (22.6% versus 9.1%; P=0.03).ConclusionsIn this first matched comparison of THVs for valve-in-valve implantations, Portico and CoreValve demonstrated differences in postprocedural hemodynamics and long-term clinical outcomes. Although this could be related to THV design characteristics, the impact of other procedural factors cannot be excluded and require further evaluation.© 2017 American Heart Association, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…