• Catheter Cardiovasc Interv · Dec 2016

    Intraprocedural assessment of mitral regurgitation during the mitraclip procedure: Impact of continuous left atrial pressure monitoring.

    • Jan Horstkotte, C Kloeser, H Beucher, E Schwarzlaender, R S von Bardeleben, and P Boekstegers.
    • Department of Cardiology, Heart Center Siegburg, Helios Klinikum Siegburg, Germany.
    • Catheter Cardiovasc Interv. 2016 Dec 1; 88 (7): 1134-1143.

    IntroductionIntraprocedural assessment of mitral regurgitation (MR) is a challenging issue during the MitraClip procedure, which might influence not only the position but also the number of MitraClips implanted. Though transesophageal echocardiography (TEE) is the predominant tool used during the MitraClip procedure, MR assessment might be facilitated by a multimodality approach including continuous and simultaneous determination of left atrial and left ventricular (LV) pressure.Methods86 consecutive patients (76.5 ± 8 years) who qualified for the MitraClip procedure were included into the study. In all patients, the multimodal assessment of MR (TEE, LV angiogram, TEE bubble evaluation, left atrial (LA) pressure => MitraScore) was performed after introducing the MitraClip guide catheter. In the first 42 patients (group A, no CAP), left atrial (LA) pressure (peak pressure of V-wave) was determined only before and after MitraClip implantation, whereas, in the subsequent 44 patients (group B, with CAP), continuous left atrial pressure monitoring (CAP) was performed.ResultsPatients with CAP (group B) had similar total procedural durations and no increase in the complication rate. MitraScore decreased from 10.5 to 3.5 in group A compared to 10.7 to *2.8 in group B (*P = 0.021 vs. group B). Whether the significant improvement of intraprocedural MR in group B translated into superior MR reduction in the conscious patient, was analyzed by transthoracic echocardiography (TTE) in a blinded fashion. Again MR reduction was significantly greater (P = 0.03) in group B (MR grade 2.8 to 0.9) as compared to group A (MR grade 2.8 to 1.3) and 2D vena contracta decreased from 0.54 ± 0.15 cm to 0.17 ± 0.10 in group B compared to group A (0.56 ± 0.19 cm to *0.23 ± 0.12; *P = 0.01 vs. group B).ConclusionsMultimodality assessment of intraprocedural MR supported by continuous left atrial pressure monitoring was associated with superior intraprocedural results translating into improved MR reduction also at the end of the hospital stay. © 2016 Wiley Periodicals, Inc.© 2016 Wiley Periodicals, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…