• Clinical biomechanics · Nov 2002

    Comparative Study

    Effect of Fuji pressure sensitive film on actual contact characteristics of artificial tibiofemoral joint.

    • Jiann-Jong Liau, Cheng-Kung Cheng, Chun-Hsiung Huang, and Wai-Hee Lo.
    • Orthopaedic Biomechanics Laboratory, Institute of Biomedical Engineering, National Yang Ming University, No. 155, Sec. 2, Li-Nung St., Shih-Pai, Taipei 112, Taiwan.
    • Clin Biomech (Bristol, Avon). 2002 Nov 1; 17 (9-10): 698-704.

    ObjectiveTo investigate the effect of inserting a Fuji pressure sensitive film into an artificial tibiofemoral joint on the actual contact mechanics.DesignThe experimental measurement and finite element analysis were used.Background. Although Fuji pressure sensitive film was widespread used for measuring the contact characteristics of artificial joint, how this measurement approaches actual contact characteristics has not yet been studied extensively.MethodTwo three-dimensional finite element models of an artificial tibiofemoral joint were constructed. The with-film-model was used to mimic the experimental setup and was verified by comparing the contact area and pressure on the simulated film calculated from finite element analysis to the measured one from the Fuji film (ultra-super low and medium grades) in the experimental test. Then the with-film-model was modified to the without-film-model in which the simulated film was removed. The contact characteristics on the film calculated from the with-film-model were represented to the measured one and the contact characteristics on the tibial component calculated from the without-film-model were represented to the actual one. The measured and actual contact characteristics were studied to investigate the effects of Fuji film on the actual contact characteristics in the tibiofemoral joint of knee prosthesis.ResultsThe contact characteristics calculated from with-film-model was reasonable agreement with measured one by Fuji film in the experimental test. The maximum difference is 13% in maximum contact pressure under a load of 3000 N. The maximum difference of contact area and pressure between the model simulating actual contact circumstance and the model with inserting a Fuji film between contacting surface are 2.4% and 14% respectively.ConclusionThis study revealed that contact area and pressure of the tibiofemoral joint of knee prosthesis measured by Fuji pressure sensitive film could be simulated by finite element analysis. The measurement of contact area in the artificial joint by using ultra-super low grade Fuji film is overestimated its actual contact area by 1.2-2.4%, but the measurement of contact pressure by using medium grade Fuji film is underestimated its actual contact pressure by 8-14%.RelevanceThis study revealed that the ultra-super low grade Fuji film is a reliable sensor to measure the contact area and the medium grade film would underestimate its actual contact pressure in the artificial tibiofemoral joint. This finding can provide a better understanding of the reliability of Fuji film to measure the contact characteristics of artificial joint in the experimental test.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…