Clinical Trial
Incident stroke is associated with common carotid artery diameter and not common carotid artery intima-media thickness.
- Joseph F Polak, Ralph L Sacco, Wendy S Post, Dhananjay Vaidya, Martinson Kweku Arnan, and Daniel H O'Leary.
- From the Department of Radiology, Tufts University School of Medicine, Boston, MA (J.F.P.); Department of Neurology, University of Miami, FL (R.L.S.); Division of Cardiology (W.S.P.) and Department of Medicine (W.S.P., D.V.), Johns Hopkins University School of Medicine, Baltimore, MD; Department of Neurology, Wake Forest School of Medicine, Winston-Salem, NC (M.K.A.); and Department of Radiology, Saint Elizabeth's Medical Center, Brighton, MA (D.H.O.).
- Stroke. 2014 May 1; 45 (5): 1442-6.
Background And PurposeThe common carotid artery interadventitial diameter is measured on ultrasound images as the distance between the media-adventitia interfaces of the near and far walls. It is associated with common carotid intima-media thickness (IMT) and left ventricular mass and might therefore also have an association with incident stroke.MethodsWe studied 6255 individuals free of coronary heart disease and stroke at baseline with mean age of 62.2 years (47.3% men), members of a multiethnic community-based cohort of whites, blacks, Hispanics, and Chinese. Ischemic stroke events were centrally adjudicated. Common carotid artery interadventitial diameter and IMT were measured. Cases with incident atrial fibrillation (n=385) were excluded. Multivariable Cox proportional hazards models were generated with time to ischemic event as outcome, adjusting for risk factors.ResultsThere were 115 first-time ischemic strokes at 7.8 years of follow-up. Common carotid artery interadventitial diameter was a significant predictor of ischemic stroke (hazard ratio, 1.86; 95% confidence interval, 1.59-2.17 per millimeter) and remained so after adjustment for risk factors and common carotid IMT with a hazard ratio of 1.52/mm (95% confidence interval, 1.22-1.88). Common carotid IMT was not an independent predictor after adjustment (hazard ratio, 0.14; 95% confidence interval, 0.14-1.19).ConclusionsAlthough common carotid IMT is not associated with stroke, interadventitial diameter of the common carotid artery is independently associated with first-time incident ischemic stroke even after adjusting for IMT. Our hypothesis that this is in part attributable to the effects of exposure to blood pressure needs confirmation by other studies.Clinical Trial Registration Urlhttp://www.clinicaltrials.gov. Unique identifier: NCT00063440.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.